A biuret method for determination of protein in normal urine.

نویسندگان

  • J Savory
  • P H Pu
  • F W Sunderman
چکیده

A biuret method has been developed which provides quantitative measurements of protein in normal urine without interference from drugs or pigments. This method is intended for use in monitoring clinical trials of new drugs-to detect nephrotoxicity. Protein is precipitated from duplicate samples of urine by addition of cold ethanolic phosphotungstic acid. The protein precipitates are separated by centrifugation and washed with ethanol. Protein from one of the duplicate samples is dissolvel in biuret reagent. Protein from the second sample is dissolved in an alkaline tartrate reagent which is identical to the biuret reagent, excepting that copper sulfate has been omitted. After 20 mm., the differential absorbance of the two samples is measured at 540 m. The limit of sensitivity for detection of protein in urine is 0.5 mg./100 ml. The coefficient of variation of replicate analyses of protein in normal urine is 4.2%. The recovery of protein added to urine averages 103 ± 3%. Analyses of urinary protein by the biuret procedure provide close correlation with measurements by an amido black staining method. Systematic search has failed to reveal interference from urinary pigments, compounds, or drugs which are normally or occasionally encountered in hospitalized patients. In 24-hr. collections of urine from 28 healthy adults, the protein concentrations averaged 6.2 mg./100 ml. (range 3.0-12.2), and the protein excretions averaged 77 mg./day (range 40-150).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of protein in urine by the biuret method.

A method for the determination of protein in urine by means of the biuret reaction was described by Hiller (1) and by Hiller, McIntosh, and Van Slyke (2), in which pure biuret prepared by Kahlbaum was used as a standard for visual calorimetry. Since Hiller (1) the biuret method has been used for the determination of urinary proteins by Price (3) and by Lehmann (4), and has been widely used in m...

متن کامل

Determination of Protein in Urine by the Biuret Method

A method for the determination of protein in urine by means of the biuret reaction was described by Hiller (1) and by Hiller, McIntosh, and Van Slyke (2), in which pure biuret prepared by Kahlbaum was used as a standard for visual calorimetry. Since Hiller (1) the biuret method has been used for the determination of urinary proteins by Price (3) and by Lehmann (4), and has been widely used in m...

متن کامل

ارزیابی کمی پروتئینوری با استفاده از نسبت پروتئین به کراتینین در نمونه‌های تصادفی ادرار افراد مبتلا به بیماریهای کلیوی

Quantitation of urinary protein excretion is important for diagnostic and prognostic purposes and to achieve the best treatment. The method most commonly used to measure urinary protein in 24 hour urine samples, are time consuming and often inaccurate. This study performed on 101 persons. Urine samples were collected three times aday. The protein/creatinine ratio(mg:mg) was measured and c...

متن کامل

Direct analysis for urinary protein with biuret reagent, with use of urine ultrafiltrate blanking: comparison with a manual biuret method involving trichloroacetic acid precipitation.

We describe a method for measuring urinary protein with a centrifugal analyzer. Biuret reagent is used, and blanking with an ultrafiltrate of urine eliminates interferences from the nonprotein, biuret-positive chromogens in urine. We compare results by this new method with those by a manual method in which trichloroacetic acid precipitation and biuret reagent are used. The new method shows good...

متن کامل

Six methods for determining urinary protein compared.

Inter-laboratory surveys have shown that "routine methods" of urinary protein determination are often unsatisfactory. Therefore, we compared six frequently used methods for determination of protein in urine with respect to linearity, within-batch and between-batch precision, comparative bias, and practicability. We assayed dilutions of human and bovine albumin and serum, and fresh and lyophiliz...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 14 12  شماره 

صفحات  -

تاریخ انتشار 1968