Performance of Silicon Photomultiplers with the CMS HCAL Front-End Electronics

نویسندگان

  • A. Heering
  • J. Rohlf
  • S. Kuleshov
  • Y. Musienko
چکیده

We have measured the performance of silicon photomultipliers (SiPMs) together with the front-end electronics developed for the Compact Muon Solenoid hadron calorimeter. We find a clean separation of the single PE peak above pedestal noise fluctuations, providing a signal to noise of about 8. The SIPMs may be useful in the near term for readout of the outer (HO) scintillators to significantly enhance the sensitivity to minimum ionizing particles for use in the muon trigger. In the longer term, the SiPMs may be useful for upgrading the readout to accommodate a luminosity upgrade.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Identification and Mitigation of Anomalous Signals in CMS Hadronic Calorimeter

The CMS HCAL detector occasionally records anomalous large energy signals that correspond to particles hitting the transducers. Anomalous signals in HCAL can also be produced by rare random discharges of the readout detectors. We present a summary of various sources of anomalous signals, the algorithms developed to identify them, and the performance of these algorithms in the CMS collision data...

متن کامل

CMS Central Hadron Calorimeter

We present a description of the CMS central hadron calorimeter. We describe the production of the 1996 CMS hadron testbeam module. We show the results of the quality control tests of the testbeam module. We present some results of the 1995 CMS hadron testbeam. The design of the CMS detector starts with the 4 T solenoidal magnet of length 13 m and inner diameter 5.9 m. The magnet determines many...

متن کامل

Readout Electronics for the Calice Ecal and Tile Hcal

The aims of the CALICE test beam program are presented. The proposed electronics readout system for the CALICE ECAL is described. It is a purposebuilt VME-based, unbuffered system. 1 The CALICE Collaboration The CALICE collaboration [1] is a group of 140 people from 24 institutes in Europe, US and Asia. The collaboration is planning a beam test program starting in 2004 to study both electromagn...

متن کامل

Cms Calorimeter Trigger Implementation and Performance

For most of the CMS ECAL, a 6 crystal by 6 crystal array of physical calorimeter towers is mapped into trigger towers. There is a 1:1 correspondence between the HCAL and ECAL trigger towers. The trigger tower size is equivalent to the HCAL physical towers, .087 x .087 in η x φ. The φ size remains constant in ∆φ and the η size remains constant in ∆η out to an η of 2.1, beyond which the η size do...

متن کامل

CMS REGIONAL CALORIMETER TRIGGER HIGH SPEED ASICs

The CMS regional calorimeter trigger system detects signatures of electrons/photons, taus, jets, and missing and total transverse energy in a deadtimeless pipelined architecture. This system contains 20 crates of custombuilt electronics. Much of the processing in this system is performed by five types of 160 MHz digital ASICs. These ASICs have been designed in the Vitesse submicron highintegrat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006