We present a structured light system to dynamically measure human chest wall motion for respiratory volume estimation. Based on a projection of an encoded color pattern and a few active markers attached to the trunk, respiratory volumes are obtained by evaluating the 3-D topographic changes of the chest wall in an anatomically consistent measuring region during respiration. Three measuring setups are established: a single-sided illuminating-recording setup for standing posture, an inclined single-sided setup for supine posture, and a double-sided setup for standing posture. Results are compared with the pneumotachography and show good agreement in volume estimations [correlation coefficient: R>0.99 (P<0.001) for all setups]. The isovolume tests present small variations of the obtained volume during the isovolume maneuver (standard deviation<0.085 L for all setups). After validation by the isovolume test, an investigation of a patient with pleural effusion using the proposed method shows pulmonary functional differences between the diseased and the contralateral sides of the thorax, and subsequent improvement of this imbalance after drainage. These results demonstrate the proposed optical method is capable of not only whole respiratory volume evaluation with high accuracy, but also regional pulmonary function assessment in different chest wall behaviors, with the advantage of whole-field measurement.
منابع مشابه
Development Of A Bio-Inspired Mechatronic Chest Wall Simulator For Evaluating The Performances Of Opto-Electronic Plethysmography
Instrumented gait analysis based on optoelectronic systems is an expensive technique used to objectively measure the human movement features and it is generally considered as the gold standard. Opto-electronic plethysmography (OEP) is a particular motion analysis system able to: (i) determine chest wall kinematic via the evaluation of marker displacements placed on the thorax and (ii) compute r...
متن کاملLaser Based Real-Time Measurement of Thorax 3D Deformation with Motion Compensation
We present a novel method for full-area, 3D visual breathing assistance with body motion compensation. The method is based on Kinect structured light triangulation sensor and uses local features detection algorithm to correct the undesired body motion during breathing training. The measuring system is contactless and operates in real-time with 30 frames per second. The feature detection algorit...
متن کاملEffect chest wall restriction in water on aerobic power, cardio-respiratory functions and swimming performance of elite female swimmers
This study is aimed to evaluate the effect of 4 weeks swimming training with chest wall restriction on aerobic power, cardio-respiratory functions and swimming performance of elite female swimmers. 24 elite female swimmers volunteered to participate in this study and were randomly divide into two groups: Control (swimming training without chest wall restriction) and experimental group (swi...
متن کاملیافتههای اختلال حرکت دیوارهای قلب در اکوکاردیوگرافی و ارزش لیدهای خلفی در تشخیص انفارکتوس میوکارد
Background: For the purpose of ascertaining myocardial infarction (MI) and ischemia, the sensitivity of the initial 12-lead ECG is inadequate. It is risky to diagnose posterior MI using only precordial reciprocal changes, since the other leads may be more optimally positioned for the identification of electrocardiographic changes. In this study, we evaluated the relationship between electrocard...
متن کاملReducing the respiratory motion artifacts in PET cardiology: A simulation study
Introduction: There are several technical features that make PET an ideal device for the noninvasive evaluation of cardiac physiology. Organ motion due to respiration is a major challenge in diagnostic imaging, especially in cardiac PET imaging. These motions reduce image quality by spreading the radiotracer activity over an increased volume, distorting apparent les...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomedical optics
دوره 15 2 شماره
صفحات -