Bio-Environment-Induced Degradation and Failure of Internal Fixation Implants.
نویسندگان
چکیده
Internal fixations provide fast healing but their failure remains problematic to patients. Here, we report an experimental study in failure of three typical cases of metals: a bent intramedullary stainless steel nail, a broken exterior pure Ti plate, and a broken intramedullary stainless steel nail. Characterization of the bent nail indicates that those metals are vulnerable to corrosion with the evidence of increased surface roughness and embrittlement. Depredated surface of the Ti plate resulted debris particles in the surrounding tissue of 15.2 ± 6.5 μm in size. Nanoparticles were observed in transmission electron microscope. The electron diffraction pattern of the debris indicates a combination of nanocrystalline and amorphous phases. The failure mode of the broken nail made of stainless steel was found to be fatigue initiated from the surface. This study clearly shows the biological-attack induced surface degradation resulting in debris and fatigue. Future design and selection of implant materials should consider such factors for improvement.
منابع مشابه
Tissue restoration after resorption of polyglycolide and poly-laevo-lactic acid screws.
Despite worldwide clinical use of bio-absorbable devices for internal fixation in orthopaedic surgery, the degradation behaviour and tissue replacement of these implants are not fully understood. In a long-term experimental study, we have determined the patterns of tissue restoration 36 and 54 months after implantation of polyglycolic acid and poly-laevo-lactic acid screws in the distal femur o...
متن کاملEvaluation of Biomass Production and Wastewater Nutrient Removal Using Microalgae: Sustainable Strategy to CO2 Bio-Fixation and Bioenergy Production Approach
Nowadays, the replacement of renewable energies such as biofuels is one of the main priorities in environmental programming and investments. This study is based on sustainable strategy towards integrating algal biomass generation as a green feedstock with wastewater treatment, CO2 bio-fixation, and bioenergy production. Therefore, the performance of Trichormus variabilis in ...
متن کاملA review of current management of metacarpal base fractures.
Metacarpal (MCP) base fractures are less commonly encountered than diaphyseal or metacarpal neck fractures. These are difficult injuries to diagnose and are challenging to treat. Neglect of these injuries, either by missed diagnosis or by inadequate treatment, causes significant disability due a poorly functioning carpo-metacarpal joint. There have been several developments in the management of...
متن کاملAn antibacterial and absorbable silk-based fixation material with impressive mechanical properties and biocompatibility
Implant-associated infections and non-absorbing materials are two important reasons for a second surgical procedure to remove internal fixation devices after an orthopedic internal fixation surgery. The objective of this study was to produce an antibacterial and absorbable fixation screw by adding gentamicin to silk-based materials. The antibacterial activity was assessed against Staphylococcus...
متن کاملResults of Plate Fixation of Third Metacarpal and Metatarsal Diaphyseal Fractures
Diaphyseal fractures of the third metacarpal (MCIII) or metatarsal (MTIII) bones are not common in horses, although they are seen regularly in equine athletes. These fractures are as many as one third of all long-bone fractures in the horse. Treatment options for MCIII/MTIII fractures include internal fixation, external coaptation, and a combination of the two. The most stable treatment method ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of functional biomaterials
دوره 6 4 شماره
صفحات -
تاریخ انتشار 2015