Modified alternating current defibrillation: a new defibrillation technique.

نویسندگان

  • Shimon Rosenheck
  • Shraga Gorni
  • Ioni Katz
  • Asaf Rabin
  • Uri Shpoliansky
  • Mendel Mandelbaum
  • Abraham Teddy Weiss
چکیده

AIMS Defibrillation is the only clinically effective treatment for ventricular fibrillation (VF). Early defibrillation improves the outcome and increases the chance of survival with full recovery. Immediate availability of a home-based defibrillator using mains-derived alternating current (AC) current will drastically improve the outcome. The aim was to develop a defibrillator based on the modulated AC, resembling biphasic configuration, and compare its efficacy, in a pig model, with a standard direct current (DC) defibrillator. METHODS AND RESULTS A computer controlled, modulated AC defibrillation system was developed using a high-voltage switch and a high-voltage transformer. The efficacy and safety was evaluated in five pigs (30-40 kg), under general anaesthesia with ketamine and isoflouran. A single quadripolar-pacing catheter was inserted percutaneously. Ventricular fibrillation was induced with rapid ventricular burst pacing, and stable VF was defibrillated after 15 s. Defibrillation threshold (DFT) was determined in each animal with AC and standard DC shock using the step-down protocol. A biphasic-like shock was used with a short isoelectric stage between the phases. The DFT with AC was 70.83 +/- 24.81 J and with DC was 65.83 +/- 12.41 J (P = 0.49). No macroscopic damage was observed after AC or DC defibrillation. CONCLUSION Modulated AC defibrillation is safe and effective as the commercially available DC defibrillation. The defibrillator is built from an inexpensive high-voltage transformer, without the need for capacitor, batteries, or routine maintenance, delivers repeated shock without any delay, and provides pacing as well. It may be an ideal platform for automatic home defibrillator.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A prospective randomized evaluation of biphasic versus monophasic waveform pulses on defibrillation efficacy in humans.

Biphasic waveforms have been suggested as a superior waveform for ventricular defibrillation. To test this premise, a prospective randomized intraoperative evaluation of defibrillation efficacy of monophasic and biphasic waveform pulses was performed in 22 survivors of out of hospital ventricular fibrillation who were undergoing cardiac surgery for implantation of an automatic defibrillator. Th...

متن کامل

A Prospective, Randomized Study

Background Recent development of a prototype singlelead unipolar transvenous defibrillator offers the possibility of device implantation with the ease of a permanent pacemaker. Lowering defibrillation energy requirements would allow for a further reduction in defibrillator generator size and enhance the feasibility of pacemaker-like placement. However, if achieving a lower defibrillation energy...

متن کامل

Cardiac Arrhythmias following Condenser Discharges and Their Dependence upon Strength of Current and Phase of Cardiac Cycle.

• The effect of electric currents upon cardiac activity has attracted increasing interest in connection with electrical defibrillation of the heart. In many cases resuscitation depends largely upon cardiac massage and ventricular defibrillation, whether the chest is open or closed." Although defibrillation of the exposed heart has been adequately studied theoretically as well as practically" th...

متن کامل

A morphologic study of canine hearts subjected to fibrillation, electrical defibrillation and manual compression.

The pathologic effects on the heart of fibrillation, countershock and manual compression have been studied in canine hearts. Survival experiments have permitted evaluation of the permanence of the damage produced. Massage of the normally beating heart produced minimal nonspecific damage. Manual compression on the fibrillating heart was seen to elicit changes more severe than those observed afte...

متن کامل

Improved defibrillation thresholds with large contoured epicardial electrodes and biphasic waveforms.

A reduction in the shock strength required for defibrillation would allow use of a smaller automatic implantable cardioverter-defibrillator and would reduce the possibility of myocardial damage by the shock. Most internal defibrillation electrodes require 5 to 25 J for successful defibrillation in human beings and in dogs. In an attempt to lower the shock strength needed for defibrillation, we ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology

دوره 11 2  شماره 

صفحات  -

تاریخ انتشار 2009