The Colorimetric Determination of Hemoglobin.*

ثبت نشده
چکیده

The method to be described for the determination of hemoglobin depends upon the comparison, in a calorimeter, of carbon monoxide hemoglobin solutions, one of which has a known hemoglobin content. Hoppe-Seyler (1) was the first to describe carbon monoxide hemoglobin and to make use of this stable combination for estimating the hemoglobin content of blood. He devised a “double pipette” for comparing the unknown carbon monoxide hemoglobin solution with the standard carbon monoxide hemoglobin solution, prepared from hemoglobin crystals; but the method never came into general use, because of the many technical difficulties involved. Haldane (2) suggested a much simpler method for comparing carbon monoxide solutions, using the apparatus employed by Gowers (3) for comparing oxyhemoglobin solutions with a picro-carmine standard. This apparatus was later employed by Sahli (4) who prepared an acid hematin standard by adding dilute hydrochloric acid to blood. A critical discussion of the various methods in use for the estimating of hemoglobin is beyond the scope of this paper. As Haldane (2) has pointed out, artificially colored solutions and tinted glass present great difficulties in standardization with a definite strength of hemoglobin solution. With a certain strength of color solution or tinted glass, it is possible to imitate quite perfectly the tint of a given hemoglobin solution provided the quality of light remains the same. Any variation from these standard conditions, either in quality of light or strength of hemoglobin in solution leads to serious errors. Haldane at-

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Chitosan Capped Silver Nanoparticles as Colorimetric Sensor for the Determination of Iron(III)

A selective, simple and low-cost method for the colorimetric determination of Fe3+ ions based on chitosan capped silver nanoparticles (Chit-AgNPs) was presented. Chitosan is a cationic polyelectrolyte and possesses amino and hydroxy groups which make it widely used as a capping agent for Ag NPs. The synthesized chitosan capped silver nanoparticles with excellent colloidal stability were charact...

متن کامل

Glycated haemoglobin: comparison between methods based upon 5-hydroxymethylfurfural determination (colorimetric or HPLC) and ion exchange chromatography (HbA1).

A comparison of methods, two based upon 5-hydroxymethylfurfural determination (colorimetric using a semi-automated procedure and HPLC) and ion exchange chromatography (HbA1 using BioRad method) was performed. The influence of variables on 5-hydroxymethylfurfural determination is reported. The dialysis step appears to be essential for an accurate determination of 5-hydroxymethylfurfural released...

متن کامل

Dye Concentrations Determination in Ternary Mixture Solution by Using Colorimetric Algorithm

This publication uses a colorimetric method based on the absorbance spectra of dye solutions to improve on Beer’s law when calculating the dye concentrations of a three-component mixture. The performance of the new method is compared with that of Beer’s law evaluated at three wavelengths, and Beer’s law evaluated at 16 wavelengths. Colorimetric method gives the best prediction of d...

متن کامل

Evaluation of a colorimetric method for determination of glycosylated hemoglobin.

We evaluated a colorimetric assay for glycosylated hemoglobin to determine the effects of several variables --oxalic acid concentration, extraneous glucose, hemoglobin concentration, hydrolysis interval, and 5-hydroxymethylfurfural destruction--and the precision. The interference seen when the blood glucose concentration exceeds 2.0 g/L (11 mmol/L) can be eliminated by washing the erythrocytes ...

متن کامل

Accuracy of Blood Loss Measurement during Cesarean Delivery

Objective This study aims to compare the accuracy of visual, quantitative gravimetric, and colorimetric methods used to determine blood loss during cesarean delivery procedures employing a hemoglobin extraction assay as the reference standard. Study Design In 50 patients having cesarean deliveries blood loss determined by assays of hemoglobin content on surgical sponges and in suction canisters...

متن کامل

New Enzymatic Colorimetric Method for the Quantitative Determination of Phenylalanine in Dry-Blood Spots

Phenylketonuria (PKU) is an autosomal recessive disorder, which is characterized by severe mental retardation, microcephaly and seizures. The symptoms of this disease can be prevented if detected soon after birth. Therefore, blood Phenylalanine (Phe) measurement is essential for the early diagnosis, treatment and dietary monitoring of PKU patients. The goal of this research was to introduce a r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003