Preconcentration of lead with Amberlite XAD-2 and Amberlite XAD-7 based chelating resins for its determination by flame atomic absorption spectrometry.

نویسندگان

  • P K Tewari
  • Ajai K Singh
چکیده

Four chelating matrices prepared by coupling Amberlite XAD-2 with chromotropic acid (AXAD-2-CA or 1), pyrocatechol (AXAD-2-PC or 2) and thiosalicylic acid (AXAD-2-TSA or 3) through azo spacer and impregnation of Amberlite XAD-7 with xylenol orange (AXAD-7-XO or 4) have been studied for enrichment of lead(II). All the four resins quantitatively sorb Pb(II) at pH 3.0-8.0 when the flow rate is maintained between 2 and 10 mlmin(-1). HNO(3) (0.5-4.0 M) instantaneously elutes Pb(II) from all the four chelating resins. The sorption capacity is in the range 16.0-186.0 mumolg(-1) and loading half time (t(1/2)) between 3.2 and 15.5 min. The tolerance limits of electrolytes (NaCl, NaBr, NaNO(3), Na(2)SO(4), Na(3)PO(4)) and cations (Ca and Mg) are reported. Phosphate interferes in the sorption with 3 and 4. The limit of detection and limit of quantification have been found to be in the ranges 2.44-7.87 and 2.76-8.64 ngml(-1), respectively. Lead has been determined in river (RSD approximately 2.6-12.8%) and tap (RSD approximately 1.8-7.2%) water samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Synthesis and application of amberlite XAD-2 functionalized with dithizone for field preconcentration and separation of trace cadmium in seawater.

A chelating resin coupling Amberlite XAD-2 functionalized with dithizone is synthesized and characterized. Dissolved cadmium is field-preconcentrated using a minicolumn packed with the synthesized resin and determined by flame atomic absorption spectrometry. Five experimental variables are evaluated. The enrichment factor of 416 is obtained for 50 mL of sampling volume, and the detection limit ...

متن کامل

Preconcentration and separation with Amberlite XAD-4 resin; determination of Cu, Fe, Pb, Ni, Cd and Bi at trace levels in waste water samples by flame atomic absorption spectrometry.

A method for the preconcentration of Cu, Fe, Pb, Ni, Cd and Bi as their diethyldithiocarbamate chelates was proposed using a column filled with Amberlite XAD-4 resin. The retained analytes on the resin were recovered with a small volume of acetone. The metal ions in the effluent were determined by a flame atomic absorption spectrometer. Different factors including pH of sample solution, sample ...

متن کامل

Determination of some trace metals by FAAS after solid-phase extraction with amberlite XAD-1180/TAN chelating resin.

A new chelating resin was synthesized by immobilizing 1-(2-thiazolylazo)-2-naphthol through the -N=N- group on Amberlite XAD-1180. The resin was used for the preconcentration of Cd(II), Co(II), Cu(II), Mn(II), Ni(II), and Pb(II) ions and their determination by flame atomic absorption spectrometry (FAAS). The influences of some analytical parameters, such as the pH, volume of the sample, flow ra...

متن کامل

Field sample preconcentration of copper in sea water using chelating minicolumns subsequently incorporated on a flow-injection-flame atomic absorption spectrometry system.

A field flow preconcentration system for copper determination in seawater is described. Seawater samples are collected and preconcentrated in situ by passing them using a peristaltic pump through a minicolumn packed with Amberlite XAD-4 impregnated with the complexing agent 1-(2-pyridylazo)-2-naphthol. Thus, copper is preconcentrated without the interference of the saline matrix. Once in the la...

متن کامل

Solid Phase Extraction, Preconcentration and Sequential Separation of U(VI), Th(IV), La(III) and Ce(III) by Octa-O-methoxy resorcin[4]arene based Amberlite XAD-4 Chelating Resin

Amberlite XAD-4 was covalently linked with octa-O-methoxy resorcin[4]arene through N=Nto form chelating resin, which has been duly characterized and successfully used for separation and preconcentration of rareearth metal ions like U(VI), Th(IV), La(III) and Ce(III). Various physiochemical parameters like pH, flow rate, sorption capacity, breakthrough studies, distribution coefficient, preconce...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Talanta

دوره 56 4  شماره 

صفحات  -

تاریخ انتشار 2002