Automated Determination of Stellar Parameters from Simulated Dispersed Images for DIVA
نویسنده
چکیده
We have assessed how well stellar parameters (Teff , log g and [M/H]) can be retrieved from low-resolution dispersed images to be obtained by the DIVA satellite. Although DIVA is primarily an all-sky astrometric mission, it will also obtain spectrophotometric information for about 13 million stars (operational limiting magnitude V ≃ 13.5 mag). Constructional studies foresee a grating system yielding a dispersion of ≃ 200nm/mm on the focal plane (first spectral order). For astrometric reasons there will be no cross dispersion which results in the overlapping of the first to third diffraction orders. The one-dimensional, position related intensity function is called a dispi (DISPersed Intensity). We simulated dispis from synthetic spectra taken from Lejeune et al. (1997) and Lejeune et al. (1998) but for a limited range of metallicites, i.e. our results are for [M/H] in the range −0.3 to 1 dex. We show that there is no need to deconvolve these low resolution signals in order to obtain basic stellar parameters. Using neural network methods and by including simulated data of DIVA’s UV telescope, we can determine Teff to an average accuracy of about 2 % for dispis from stars with 2000 K ≤ Teff ≤ 20000 K and visual magnitudes of V = 13 mag (end of mission data). log g can be determined for all temperatures with an accuracy better than 0.25 dex for magnitudes brighter than V = 12 mag. For low temperature stars with 2000 K ≤ Teff ≤ 5000 K and for metallicities in the range −0.3 to +1 dex a determination of [M/H] is possible (to better than 0.2 dex) for these magnitudes. For higher temperatures, the metallicity signatures are exceedingly weak at dispi resolutions so that the determination of [M/H] is there not possible. Additionally we examined the effects of extinction E(B − V ) on dispis and found that it can be determined to better than 0.07 mag for magnitudes brighter than V = 14 mag if the UV information is included.
منابع مشابه
Fast object detection for use onboard satellites
We propose an object detection algorithm which is efficient and fast enough to be used in (almost) real time with the limited computer capacities onboard satellites. For stars below the saturation limit of the CCD detectors it is based on a four neighbourhood local maximum criterion in order to find the centre of a stellar image. For saturated stars it is based on the assumption that the image ...
متن کاملAutomatic measurement of instantaneous changes in the walls of carotid artery with sequential ultrasound images
Introduction: This study presents a computerized analyzing method for detection of instantaneous changes of far and near walls of the common carotid artery in sequential ultrasound images by applying the maximum gradient algorithm. Maximum gradient was modified and some characteristics were added from the dynamic programming algorithm for our applications. Methods: The algorithm was evaluat...
متن کاملAutomated differentiation of benign and malignant liver tumors by Ultrasound Images
Background & Aims: Early detection and reliable differentiation of benign and malignant liver tumors could lead to improved cure rate and costs. Ultrasound image (US) is a convenient medical imaging method for interpreting liver tumors. Visual inspection of ultrasound images sometimes is combined with error and needs biopsy to confirm whether a tumor would be benign or malignant. The aim of thi...
متن کاملNovel Automated Method for Minirhizotron Image Analysis: Root Detection using Curvelet Transform
In this article a new method is introduced for distinguishing roots and background based on their digital curvelet transform in minirhizotron images. In the proposed method, the nonlinear mapping is applied on sub-band curvelet components followed by boundary detection using energy optimization concept. The curvelet transform has the excellent capability in detecting roots with different orient...
متن کاملA Semi-Automated Algorithm for Segmentation of the Left Atrial Appendage Landing Zone: Application in Left Atrial Appendage Occlusion Procedures
Background: Mechanical occlusion of the Left atrial appendage (LAA) using a purpose-built device has emerged as an effective prophylactic treatment in patients with atrial fibrillation at risk of stroke and a contraindication for anticoagulation. A crucial step in procedural planning is the choice of the device size. This is currently based on the manual analysis of the “Device Landing Zone” fr...
متن کامل