Multisite Delayed Feedback for Electrical Brain Stimulation

نویسندگان

  • Oleksandr V. Popovych
  • Peter A. Tass
چکیده

Demand-controlled deep brain stimulation (DBS) appears to be a promising approach for the treatment of Parkinson's disease (PD) as revealed by computational, pre-clinical and clinical studies. Stimulation delivery is adapted to brain activity, for example, to the amount of neuronal activity considered to be abnormal. Such a closed-loop stimulation setup might help to reduce the amount of stimulation current, thereby maintaining therapeutic efficacy. In the context of the development of stimulation techniques that aim to restore desynchronized neuronal activity on a long-term basis, specific closed-loop stimulation protocols were designed computationally. These feedback techniques, e.g., pulsatile linear delayed feedback (LDF) or pulsatile nonlinear delayed feedback (NDF), were computationally developed to counteract abnormal neuronal synchronization characteristic for PD and other neurological disorders. By design, these techniques are intrinsically demand-controlled methods, where the amplitude of the stimulation signal is reduced when the desired desynchronized regime is reached. We here introduce a novel demand-controlled stimulation method, pulsatile multisite linear delayed feedback (MLDF), by employing MLDF to modulate the pulse amplitude of high-frequency (HF) DBS, in this way aiming at a specific, MLDF-related desynchronizing impact, while maintaining safety requirements with the charge-balanced HF DBS. Previously, MLDF was computationally developed for the control of spatio-temporal synchronized patterns and cluster states in neuronal populations. Here, in a physiologically motivated model network comprising neurons from subthalamic nucleus (STN) and external globus pallidus (GPe), we compare pulsatile MLDF to pulsatile LDF for the case where the smooth feedback signals are used to modulate the amplitude of charge-balanced HF DBS and suggest a modification of pulsatile MLDF which enables a pronounced desynchronizing impact. Our results may contribute to further clinical development of closed-loop DBS techniques.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pulsatile desynchronizing delayed feedback for closed-loop deep brain stimulation

High-frequency (HF) deep brain stimulation (DBS) is the gold standard for the treatment of medically refractory movement disorders like Parkinson's disease, essential tremor, and dystonia, with a significant potential for application to other neurological diseases. The standard setup of HF DBS utilizes an open-loop stimulation protocol, where a permanent HF electrical pulse train is administere...

متن کامل

TRANSLATIONAL PHYSIOLOGY Auditory Cortical Responses to Electrical Stimulation of the Inferior Colliculus: Implications for an Auditory Midbrain Implant

Lim, Hubert H. and David J. Anderson. Auditory cortical responses to electrical stimulation of the inferior colliculus: implications for an auditory midbrain implant. J Neurophysiol 96: 975–988, 2006. First published May 24, 2006; doi:10.1152/jn.01112.2005. The success and limitations of cochlear implants (CIs) along with recent advances in deep brain stimulation and neural engineering have mot...

متن کامل

Electrical multisite stimulation of the isolated chicken retina

Visual prostheses such as subretinal implants are intended for electrical multisite excitation of the retinal network. To investigate relevant issues like spatial resolution and operational range, we have developed an in vitro method using microelectrode arrays to stimulate isolated retinae. Ganglion cell activity in the chicken retina evoked by distally applied spatial voltage patterns consist...

متن کامل

Decoupling of oscillatory ensembles by mixed nonlinear delayed feedback

Synchronization processes are of crucial importance for brain function. Well-coordinated synchrony within and between neuronal populations appears to be an important mechanisms for neuronal signaling and information processing. In contrast, pathologically strong synchronization may severely impair brain function. For instance, resting tremor in Parkinson’s disease is caused by a synchronized po...

متن کامل

Genetic Feedforward-Feedback Controller for Functional Electrical Stimulation Control of Elbow Joint Angle

Background: Functional electrical stimulation (FES) is the most commonly used system for restoring functions after spinal cord injury (SCI). Objective: In this study we investigated feedback PID and feedforward-feedback P-PID controllers for regulating the elbow joint angle. Methods: The controllers were tuned based on a nonlinear muculoskeletal model containing two links, one joint with one de...