Aortic annulus sizing: echocardiographic versus computed tomography derived measurements in comparison with direct surgical sizing.

نویسندگان

  • Jörg Kempfert
  • Arnaud Van Linden
  • Lukas Lehmkuhl
  • Ardawan J Rastan
  • David Holzhey
  • Johannes Blumenstein
  • Friedrich W Mohr
  • Thomas Walther
چکیده

OBJECTIVES The precise sizing of the aortic annulus is crucial in order to select the most appropriate valve size for transcatheter aortic valve implantation (TAVI). Owing to the closed heart situation in TAVI, sizing has to be performed based on preoperative imaging when compared with direct sizing during conventional procedures. The aim of the study was to evaluate valve sizing performed either by CT-scan or by echocardiography by comparing these imaging-based measurements with direct intraoperative sizing. METHODS Prior to the standard conventional aortic valve replacement, 26 patients underwent cardiac CT-scan and echocardiographic examination. Maximal annular diameter was measured by echocardiography at end-diastole and end-systole, including the leaflet calcifications. The CT-scan maximal, minimal and mean diameters were measured as well as the 'effective' diameter (CT(eff)). CT(eff) represents the diameter of a circle with the exact same area as the measured area of the annular circumference reconstructed from the CT-data set. Direct intraoperative diameters were measured after decalcification using metric sizers. RESULTS CT(eff) and end-systolic echocardiographic diameters showed best agreement with intraoperative direct sizing (intraop) in the Bland-Altman analysis [mean difference for transoesophageal echocardiography (TEE) vs intraop 0.5 mm (limits of agreement -2.5-3.5); mean difference for transthoracic echocardiography (TTE) vs intraop 0.38 mm (limits of agreement -3.28-4.03) and CT(eff) vs intraop -0.56 (limits of agreement -3.16-2.05)]. In patients with an oval-shaped annulus, CT(eff) demonstrated the best agreement with intraop [mean difference -0.32 (limits of agreement -2.29 to 1.66)]. CONCLUSIONS Both the 'effective' CT diameter and end-systolic TEE values are the most reliable approaches for preoperative aortic annulus sizing. In patients with a pronounced oval-shaped annulus, the 'effective' CT diameter seems to be the method of choice. Therefore, aortic annulus measurement using 'effective' CT diameters should be included into current recommendations for TAVI sizing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Can balloon aortic valvuloplasty help determine appropriate transcatheter aortic valve size?

OBJECTIVES We sought to study the potential role of balloon aortic valvuloplasty (BAV) in sizing the aortic annulus in patients before transcatheter heart valve (THV) implantation. BACKGROUND Despite clinicians' growing experience with THV procedures, the best method of annulus sizing remains unclear. METHODS Twenty-three patients with aortic stenosis (<1.0 cm(2)) who were undergoing surgic...

متن کامل

Three-dimensional echocardiography vs. computed tomography for transcatheter aortic valve replacement sizing.

AIMS The accuracy of transcatheter aortic valve replacement (TAVR) sizing using three-dimensional transoesophageal echocardiography (3D-TEE) compared with the gold-standard multi-slice computed tomography (MSCT) remains unclear. We compare aortic annulus measurements assessed using these two imaging modalities. METHODS AND RESULTS We performed a single-centre prospective cohort study, includi...

متن کامل

Relationship of Annular Sizing Using Multidetector Computed Tomographic Imaging and Clinical Outcomes After Self-Expanding CoreValve Transcatheter Aortic Valve Replacement.

BACKGROUND Multidetector computed tomography is useful for determining the appropriate transcatheter heart valve (THV) size in patients with severe aortic stenosis who are suboptimal surgical candidates. The relationship between adherence to the recommended CoreValve sizing algorithm and clinical outcomes is not known. METHODS AND RESULTS We evaluated 1023 patients with severe aortic stenosis...

متن کامل

SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR).

Computed tomography (CT) plays an important role in the workup of patients who are candidates for implantation of a catheter-based aortic valve, a procedure referred to as transcatheter aortic valve implantation (TAVI) or transcatheter aortic valve replacement (TAVR). Contrast-enhanced CT imaging provides information on the suitability of the peripheral access vessels to accommodate the relativ...

متن کامل

Aortic annular sizing for transcatheter aortic valve replacement using cross-sectional 3-dimensional transesophageal echocardiography.

OBJECTIVES This study compared cross-sectional three-dimensional (3D) transesophageal echocardiography (TEE) to two-dimensional (2D) TEE as methods for predicting aortic regurgitation after transcatheter aortic valve replacement (TAVR). BACKGROUND Data have shown that TAVR sizing using cross-sectional contrast computed tomography (CT) parameters is superior to 2D-TEE for the prediction of par...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 42 4  شماره 

صفحات  -

تاریخ انتشار 2012