The effectiveness of transvenous leads extractions implanted more than 10 years before.
نویسندگان
چکیده
BACKGROUND The increasing number of patients with cardiac implantable electronic devices (CIEDs) causes a rise in the absolute percentage of individuals qualifying for a transvenous lead extraction (TLE) due to infectious, vascular or lead failure related indications. As the survival time prolongs, TLE procedures more and more often concern the electrodes of long- -term functioning. Authors provide a retrospective analysis of the effectiveness and safety of TLE performed on leads implanted at least 10 years before the extraction. METHODS Between 2008 and 2012 we performed TLE of 364 electrodes in 217 patients. Out of these, 66 (18.1%) leads in 43 (19.8%) patients had been implanted for at least 10 years. The mean dwelling time for electrodes was 161 months (120 to 330). In 62% of cases CIED-related infection was an indication for TLE. The following extracting techniques were used: manual direct traction, device traction, mechanical telescopic sheaths, autorotational cutting sheaths and femoral approach. RESULTS Fifty-eight pacemakers and 8 defibrillating leads were extracted. Sixty-three (95%) completely, in the remaining 3 cases the clinical success was achieved with the small portion of the lead left into the vascular space. No major procedure complications were observed; minor complications were found in 3 (6%) patients. CONCLUSIONS TLE with the use of various endovascular techniques is an effective and safe method for treating infectious, vascular and mechanical complications of long-lasting CIEDs therapy.
منابع مشابه
Extraction of old pacemaker or cardioverter-defibrillator leads by laser sheath versus femoral approach.
BACKGROUND Some operators routinely extract chronically implanted transvenous leads from a femoral, whereas others prefer a superior approach. This prospective study compared the safety and effectiveness of laser sheaths versus femoral snare extractions. METHODS AND RESULTS The single-center study comprised 101 patients referred for unequivocal indications to extract > or =1 transvenous lead(...
متن کاملffect of Chlorhexidine on Prevention of Local Infection in Temporary Transvenous Pacemaker Catheter Site
Background and Objectives: The local infection of temporary transvenous pacemaker catheter site is a common hospital acquired infections. This study aimed to assess the effect of the Chlorhexidine Glaciate 2% on prevention of local infection on temporary transvenous pacemaker catheter site. Materials and Methods: In this 7-month randomized controlled trial, 100 patients having temporary transve...
متن کاملTransvenous Implantable Cardioverter-Defibrillator Lead Reliability: Implications for Postmarket Surveillance
BACKGROUND As implantable cardioverter-defibrillator technology evolves, clinicians and patients need reliable performance data on current transvenous implantable cardioverter-defibrillator systems. In addition, real-world reliability data could inform postmarket surveillance strategies directed by regulators and manufacturers. METHODS AND RESULTS We evaluated Medtronic Sprint Quattro, Boston...
متن کاملLong term transvenous ventricular pacing in adults with congenital abnormalities of the heart and great arteries.
Improved techniques of transvenous pacing have made it possible to use this approach in various congenital cardiac abnormalities. Transvenous active fixation pacing leads were implanted in seven patients aged 15 to 81 years with abnormal venous, atrioventricular, or ventriculoarterial connections with successful ventricular pacing.
متن کاملInitial experience with larger laser sheaths for the removal of transvenous pacemaker and implantable defibrillator leads.
BACKGROUND In a previous randomized trial, the 12F laser sheath removed pacing leads via the implant vein more successfully than traditional mechanical tools alone. Two larger sizes of laser sheath, the 14F and 16F models, were developed to extract defibrillator leads and large-diameter pacing leads implanted for the chronic. These devices use pulsed ultraviolet laser light to core though fibro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Cardiology journal
دوره 21 4 شماره
صفحات -
تاریخ انتشار 2014