Long-term field characterization of tapered element oscillating microbalance and modified tapered element oscillating microbalance samplers in urban and rural New York State locations.

نویسندگان

  • James J Schwab
  • John Spicer
  • Kenneth L Demerjian
  • Jeffrey L Ambs
  • Henry D Felton
چکیده

Long-term field comparisons of continuous and integrated filter measurements of mass concentrations of particulate matter (PM) with an aerodynamic diameter less than or equal to 2.5 microm (PM2.5) were performed at rural and urban sites in New York State. Two versions of the continuous tapered element oscillating microbalance (TEOM) mass monitor are deployed at each site, in addition to Federal Reference Method filter samplers. Data are grouped into monthly averages to retain and demonstrate seasonal differences. Strong seasonal dependence is observed-the TEOM monitors with the heated sensors are biased systematically low with respect to the Federal Reference Method measurements during the cold season. For the rural site, the average bias for the sample equilibration system (SES)-equipped and standard TEOM monitors is 14 and 24%, respectively. At this location, the TEOM monitor measurements were biased low for all 34 months. For the urban site, the average bias for the SES and standard TEOM monitors is 8 and 18%, respectively. At this location, the TEOM monitor measurements are as likely to be biased high as low during the warm-season months. The hour averaged data from the two versions of the TEOM monitor are also compared, and also indicate that the SES-equipped version of the TEOM monitor captures 7-11% more PM2.5 mass at these locations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of measured total suspended particulate matter concentrations using tapered element oscillating microbalance and a total suspended particulate sampler.

A comparison of the concentration of the total suspended particulate (TSP) matter measured by the tapered element oscillating microbalance (TEOM) monitor and the isokinetic TSP samplers developed at the University of Illinois was carried out in several types of confinement livestock buildings. In a majority of the measurements done, the dust concentration measured by the TEOM monitor was lower ...

متن کامل

Direct assessment of molecular transport in mordenite: dominance of surface resistances.

For the first time, macroscopic and microscopic diffusion measurements were combined for a single system: n-hexane in mordenite. Using tapered element oscillating microbalance and IR microimaging results, we unequivocally proved the dominant role of surface barriers for molecular transport.

متن کامل

Impact of the 2002 Canadian forest fires on particulate matter air quality in Baltimore city.

With increasing evidence of adverse health effects associated with particulate matter (PM), the exposure impact of natural sources, such as forest fires, has substantial public health relevance. In addition to the threat to nearby communities, pollutants released from forest fires can travel thousands of kilometers to heavily populated urban areas. There was a dramatic increase in forest fire a...

متن کامل

Time resolved characterization of diesel particulate emissions. 1. Instruments for particle mass measurements.

The measurement of diesel vehicle exhaust particulate mass is currently accomplished using filter collection methods according to the Code of Federal Regulations (CFR). Such filter methods limit time resolution to a minimum of several minutes, making it impossible to study emissions during transient operating conditions. Extensive testing of five different measurement methods has demonstrated t...

متن کامل

Explicit Stiffness of Tapered and Monosymmetric i Beam-Columns

A formulation for finite element analysis of tapered and  monosymmetric I shaped beam-columns is presented. This is a general way to analyze these types of complex elements. Based upon the formulation, member stiffness matrix is obtained explicitly. The element considered has seven nodal degrees of freedom. In addition, the related stability matrix is found. Numerical studies of the aforementio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the Air & Waste Management Association

دوره 54 10  شماره 

صفحات  -

تاریخ انتشار 2004