Turbo spin-echo diffusion-weighted MR of ischemic stroke.

نویسندگان

  • K O Lövblad
  • P M Jakob
  • Q Chen
  • A E Baird
  • G Schlaug
  • S Warach
  • R R Edelman
چکیده

PURPOSE Our objective was to determine whether a multisection technique, diffusion-weighted half-Fourier single-shot turbo spin-echo (HASTE) imaging, can compensate for the drawbacks common to other diffusion-weighted techniques; specifically, the need for echo-planar technology and the presence of susceptibility artifacts in areas close to the skull base. METHODS Forty subjects who were referred to the stroke service with signs of acute (less than 24 hour) neurologic dysfunction were included in this prospective study. MR imaging of the brain was performed with diffusion-weighted echo-planar and diffusion-weighted HASTE sequences. The images obtained with both sequences were analyzed for the presence of hyperintensities corresponding to ischemic lesions as well as for the presence of image artifacts and distortions. RESULTS Diffusion-weighted HASTE images showed areas of hyperintensity corresponding to the infarcts present on diffusion-weighted echo-planar imaging studies without distortion or susceptibility artifacts in all the patients who had a stroke. Twelve patients had no acute ischemic lesions; of these, five had other findings, six had normal findings, and in one patient, a hyperintensity seen on diffusion-weighted echo-planar images proved to be an artifact on diffusion-weighted HASTE images. CONCLUSIONS Diffusion-weighted HASTE is equal to diffusion-weighted echo-planar imaging in the detection of early ischemia. Because of the absence of significant image distortions and other artifacts, diffusion-weighted HASTE permits fast multiplanar imaging in artifact-prone regions, such as the posterior fossa and the inferior frontal and temporal lobes. Diffusion imaging can be performed on conventional systems with strengths of 1.5 T that do not have echo-planar imaging capabilities.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Single-shot, turbo spin-echo, diffusion-weighted imaging versus spin-echo-planar, diffusion-weighted imaging in the detection of acquired middle ear cholesteatoma.

Diagnosis of acquired middle ear cholesteatoma on MR imaging is mostly done on late postgadolinium T1-weighted MR images and/or echo-planar (EPI) diffusion-weighted (DWI) MR images. We describe the appearance of a case of a complicated attical middle ear cholesteatoma on single-shot (SS) turbo spin-echo (TSE) DWI compared with EPI-DWI. This case suggests a higher reliability of SS TSE-DWI in th...

متن کامل

Neonatal cerebral infarction diagnosed by diffusion-weighted MRI: pseudonormalization occurs early.

BACKGROUND Seizures in the neonatal period may be the single symptom of acute ischemic cerebral infarction. It may be difficult to establish the diagnosis in the acute phase by the use of ultrasound, CT, and conventional MRI because of the high water content of the immature brain. Diffusion-weighted (DW) MRI is a very sensitive and fast imaging modality to visualize acute ischemic stroke in inf...

متن کامل

Diffusion-Weighted MR Imaging and Ischemic Stroke

Magnetic resonance imaging (MR) of ischemic cerebrovascular events with standard T1and T2-weighted spin-echo techniques is widely employed. Standard MR demonstrates vascular changes such as the absence of a flow void and the presence of arterial enhancement within 2-4 hours of ischemic stroke onset in some cases ( 1 ). The earliest morphologic change in the brain parenchyma, swelling, is visibl...

متن کامل

Diffusion-weighted MR imaging of acute stroke: correlation with T2-weighted and magnetic susceptibility-enhanced MR imaging in cats.

We evaluated the temporal and anatomic relationships between changes in diffusion-weighted MR image signal intensity, induced by unilateral occlusion of the middle cerebral artery in cats, and tissue perfusion deficits observed in the same animals on T2-weighted MR images after administration of a nonionic intravascular T2 shortening agent. Diffusion-weighted images obtained with strong diffusi...

متن کامل

Comparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm

Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 19 2  شماره 

صفحات  -

تاریخ انتشار 1998