Radionuclide left ventricular ejection fraction: a comparison of three methods.

نویسندگان

  • A D Hains
  • I Al-Khawaja
  • D A Hinge
  • A Lahiri
  • E B Raftery
چکیده

Three commercially available computer programs (a semiautomatic method, a manual method, and a regional method) were used to calculate left ventricular ejection fraction from the equilibrium multiple gated radionuclide ventriculograms obtained from 24 normal male subjects and 20 men with heart failure. In the normal subjects the ejection fraction values calculated by each method were significantly different (mean SD) difference between semiautomatic and manual 3.3 (5.8); between semiautomatic and regional 12.0 (6.3); and between manual and regional 8.7 (6.9]. In the patients with heart failure the ejection fraction values calculated by the semiautomatic method differed significantly from those calculated by the manual and regional methods (mean (SD) difference between semiautomatic and manual 3.4 (4.7); between semiautomatic and regional 4.9 (4.9); and between manual and regional 1.5 (6.2]. The ejection fraction values obtained by the semiautomatic method were generally higher and more consistent than those derived from the manual and regional methods. An ejection fraction of greater than or equal to 50% with the semiautomatic method would be regarded as normal but if the same normal range was applied to the regional method nine (38%) of the 24 normal subjects would appear to have an abnormal left ventricular function. Clinicians should be aware that the method used to generate a time-activity curve is an important consideration in the calculation of ejection fraction. Each centre should establish its own range and reproducibility for the method it uses to measure ejection fraction. These values should not be assumed to apply to any other method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Regional Ejection Fraction: A Quantitative Radionuclide Index of Regional Left Ventricular Performance

Radionuclide measurements of regional left ventricular ejection fraction were evaluated as a quantitative index of regional left ventricular function. Left ventricular regional ejection fractions were derived from background-corrected, time-activity curves in 43 patients assessed by both gated equilibrium radionuclide angiocardiography and left ventricular contrast angiography. From a single, m...

متن کامل

Regional ejection fraction: a quantative radionuclide index of regional left ventricular performance.

Radionuclide measurements of regional left ventricular ejection fraction were evaluated as a quantitative index of regional left ventricular function. Left ventricular regional ejection fractions were derived from background-corrected, time-activity curves in 43 patients assessed by both gated equilibrium radionuclide angiocardiography and left ventricular contrast angiography. From a single, m...

متن کامل

Non-invasive measurement of left ventricular function in coronary artery disease. Comparison of first pass radionuclide ventriculography, M-mode echocardiography, and systolic time intervals.

Fifty consecutive patients having had cardiac catheterisation for coronary artery disease also underwent testing by three non-invasive methods commonly employed for assessment of left ventricular function. These included the first pass radionuclide ejection fraction, fractional shortening of the M-mode echocardiographic left ventricular internal dimension, and pre-ejection period/left ventricul...

متن کامل

The effect of eight weeks of moderate-intensity endurance training on myocardial capillary density, ejection fraction and left ventricular shortening fraction in male rats with myocardial infarction

Background and objective: Vascular obstruction and impaired blood flow and oxygen delivery cause a myocardial infarction and limit a personchr('39')s function. Therefore, finding a way to create new arteries and replace blocked arteries has always been of interest to researchers, including exercise physiologists. Therefore, this study was conducted to evaluate the effect of eight weeks of moder...

متن کامل

Quantitative radionuclide angiocardiography. Determination of left ventricular ejection fraction in children.

A method is described for measuring left ventricular ejection fraction which uses high frequency computer recording of gamma scintillation camera data and peripheral venous injectinon of technetium-99m as sodium pertechnetate. Data from mechanical model experiments are used to show feasibility of this method. A phantom experiment is described which was used to develop a technique for accurate d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British heart journal

دوره 57 3  شماره 

صفحات  -

تاریخ انتشار 1987