Pseudo forward ray-tracing: a new method for surface validation in cornea topography.

نویسندگان

  • Victor Arni D P Sicam
  • Joris J Snellenburg
  • Rob G L van der Heijde
  • Ivo H M van Stokkum
چکیده

PURPOSE A pseudo forward ray-tracing (PFRT) algorithm is developed to evaluate surface reconstruction in corneal topography. The method can be applied to topographers where one-to-one correspondence between mire and image points can be established. METHODS The PFRT algorithm was applied on a corneal topographer designed and constructed at the VU University Medical Center, Amsterdam, The Netherlands. Performance of the algorithm was evaluated using artificial test surfaces and two sample eyes. The residual output of the PFRT algorithm is displayed as pixel displacements of actual feature points on the corneal image. Displacement of 1 pixel indicates submicrometer corneal height accuracy. RESULTS PFRT residual increases with complexity of the measured surface. Using Zernike radial order 6, the mean residual for the artificial surfaces is subpixel. The mean residual for the regular cornea and the irregular cornea is 1.16 and 2.94 respectively. To some extent, increasing the Zernike radial order improves the accuracy. The improvement from order 6 to 20 is factor 2.3 for the irregular cornea. Using the residuals to further improve the accuracy brought local changes as high as 0.28 D in some areas of the reconstructed corneal power map. CONCLUSION PFRT can be used to evaluate how close a reconstructed corneal surface is to the actual one. The residue information obtained from this algorithm can be displayed simultaneously with the corneal image. This provides accurate information about the corneal shape that is useful for application in laser refractive surgery.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Forward ray tracing for image projection prediction and surface reconstruction in the evaluation of corneal topography systems.

A forward ray tracing (FRT) model is presented to determine the exact image projection in a general corneal topography system. Consequently, the skew ray error in Placido-based topography is demonstrated. A quantitative analysis comparing FRT-based algorithms and Placido-based algorithms in reconstructing the front surface of the cornea shows that arc step algorithms are more sensitive to noise...

متن کامل

Validation of the estimation of corneal aberrations from videokeratography in keratoconus.

PURPOSE To validate the estimation of corneal aberrations from videokeratography against a laser ray tracing technique that measured total eye aberrations, in eyes without keratoconus (ie, cornea-dominated wave aberrations). METHODS We measured total and corneal wave aberrations of three eyes diagnosed with keratoconus by slit-lamp microscopy and corneal topography: two eyes from one patient ...

متن کامل

Three-dimensional ray tracing on Delaunay-based reconstructed surfaces.

A method of ray tracing for free-form optical surfaces has been developed. The ray tracing through such surfaces is based on Delaunay triangulation of the discrete data of the surface and is related to finite-element modeling. Some numerical examples of applications to analytical, noisy, and experimental free-form surfaces (in particular, a corneal topography map) are presented. Ray-tracing res...

متن کامل

Ray-tracing and Interferometry in Schwarzschild Geometry

Here, we investigate the possible optical anisotropy of vacuum due to gravitational field. In doing this, we provide sufficient evidence from direct coordinate integration of the null-geodesic equations obtained from the Lagrangian method, as well as ray-tracing equations obtained from the Plebanski’s equivalent medium theory. All calculations are done for the Schwarzschild geometry, which resu...

متن کامل

Efficient Coupling of Monte Carlo and Level Set Methods for Topography Simulation

We have developed a topography simulation method which combines advanced level set techniques for surface evolution with Monte Carlo flux calculation. The result is an algorithm with an overall complexity and storage requirement scaling like O(N logN) with surface disretization. The calculation of particle trajectories is highly optimized, since spatial partitioning is used to accelerate ray tr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Optometry and vision science : official publication of the American Academy of Optometry

دوره 84 9  شماره 

صفحات  -

تاریخ انتشار 2007