Serum immunoglobulin E levels predict human airway reactivity in vitro.

نویسندگان

  • D Schmidt
  • N Watson
  • E Ruehlmann
  • H Magnussen
  • K F Rabe
چکیده

BACKGROUND Airway hyperresponsiveness to non-specific stimuli is one characteristic feature of airway diseases such as bronchial asthma and chronic bronchitis. Until now, studies aiming to demonstrate a relationship between in vivo conditions associated with airway hyperreactivity and in vitro airway responsiveness have been inconclusive. OBJECTIVE Since serum immunoglobulin (Ig) E is believed to be one determinant of airway reactivity in vivo, we studied whether in vitro airway reactivity in lung resection material from patients with elevated levels of serum IgE was increased as compared with patients with undetectable IgE. By this approach, we aimed to elucidate the role of circulating IgE for bronchial smooth muscle reactivity in vitro. METHODS Bronchial rings from nine patients with total serum IgE levels above 200 U/mL and 10 patients with total serum IgE levels below 10 U/mL were passively sensitized, i.e. incubated overnight with buffer or sensitizing serum containing high levels of total IgE (> 250 U/mL). Afterwards, contractile responses to histamine were assessed in the organ bath. RESULTS Histamine responsiveness was significantly increased in airways obtained from patients with IgE levels above 200 U/mL as compared with airways from patients with IgE levels below 10 U/mL (P < 0.05). Passive sensitization of bronchi from patients with low IgE significantly increased histamine responsiveness, as compared with non-sensitized controls from the same patients (P < 0.05). In contrast, passive sensitization of airways from patients with elevated IgE did not further increase responsiveness. There was no difference in histamine reactivity between non-passively sensitized and passively sensitized tissue preparations from patients with IgE above 200 U/mL and passively sensitized tissues from patients with IgE below 10 U/mL. CONCLUSION Our findings reveal that elevated levels of serum IgE predict airway hyperresponsiveness to histamine in vitro. At the same time, they indicate that the in vitro model of passive sensitization, in addition to its ability to induce allergen responses, also mimics conditions of non-specific airway hyperreactivity, which are relevant under in vivo conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Serum immunoglobulin E and immunoglobulin G reactivity to Agaricus bisporus proteins in mushroom cultivation workers

Background and Purpose: Although molds are regarded as the main fungal allergen sources, evidence indicates that spores of Basidiomycota including Agaricus bisporus (A. bisporus) can be also found at high concentrations in the environment and may cause as many respiratory allergies as molds. The aim of the present study was to evaluate specific immunoglobulin E (IgE) and immunoglobulin G (IgG) ...

متن کامل

Relationship between cholinergic airway tone and serum immunoglobulin E in human subjects.

It has recently been shown that immunoglobulin (Ig)E facilitates the cholinergic bronchoconstrictor pathway in human tissue in vitro. However, whether this occurs in humans in vivo has not been clarified. In this study, the bronchodilator responses were examined to inhalation of a submaximal dose of the anticholinergic agent oxitropium bromide (600 microg) in normal and allergic subjects with v...

متن کامل

Evaluation of association of blood and bronchoalveolar eosinophil numbers and serum total immunoglobulin E concentration with the expression of nonspecific airway reactivity in dogs.

OBJECTIVE To characterize the relation between bronchoalveolar and blood eosinophil numbers, serum total IgE concentration, and nonspecific airway reactivity in healthy dogs. ANIMALS 26 healthy Beagles. PROCEDURE Prior to measurement of nonspecific airway responsiveness, dogs were anesthetized and bronchoscopy was performed to recover bronchoalveolar lavage (BAL) fluid. Repeated measurement...

متن کامل

Dissociation of airway hyperresponsiveness from immunoglobulin E and airway eosinophilia in a murine model of allergic asthma.

Nonspecific airway hyperresponsiveness (AHR) is a hallmark of human asthma. Both airway eosinophilia and high serum levels of total and antigen-specific immunoglobulin E (IgE) are associated with AHR. It is unclear, however, whether either eosinophilia or increased IgE levels contribute directly to, or predict, the development of AHR. Investigations conducted with various murine models of asthm...

متن کامل

Is There Correlation between Chronic Idiopathic Urticaria and Elevated Serum IgE? A Pilot Study

Background: The etiology of urticaria is recognized only in a minority of cases. Allergies to a wide variety of agents have been suspected, as well as hyper reactivity to food additives or drugs. Recently, autoimmune reaction to immunoglobulin E (IgE) and later to high-affinity IgE receptors on mast cells has been reported. The aim of this study was to show elevated serum IgE levels in the pati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical and experimental allergy : journal of the British Society for Allergy and Clinical Immunology

دوره 30 2  شماره 

صفحات  -

تاریخ انتشار 2000