Catecholamine interference in enzymatic creatinine assays.

نویسندگان

  • Amy K Saenger
  • Christina Lockwood
  • Christine L Snozek
  • Thomas C Milz
  • Brad S Karon
  • Mitchell G Scott
  • Allan S Jaffe
چکیده

BACKGROUND Enzymatic creatinine assays are routinely used in clinical laboratories to provide more accurate estimated glomerular filtration rates and to avoid a perceived lack of analytical specificity associated with picrate (Jaffe) methods. Negative interferences with the enzymatic creatinine assay, which we noted in several patients on dopamine or dobutamine, prompted our further investigation into interference of catecholamines with enzymatic methods. METHODS Spiked solutions of dopamine, dobutamine, epinephrine, and norepinephrine were added to pooled sera at catecholamine concentrations consistent with clinically relevant dosing. Creatinine was measured enzymatically on the Roche P-Modular, Ortho Clinical Diagnostics Vitros 350, and Abbott i-STAT. Jaffe methods were performed on the Roche P-Modular and Siemens Dimension RxL. In 10 patients receiving dopamine and/or dobutamine via a venous or arterial line we evaluated and compared the extent of in vivo creatinine interference in paired serum samples obtained by venipuncture and from indwelling catheters. RESULTS All catecholamines caused significant negative interference with the Roche enzymatic creatinine assay, most pronounced for dopamine and dobutamine. The Vitros enzymatic assay demonstrated slight negative interferences, and i-STAT enzymatic and Jaffe methods were unaffected by the presence of catecholamines. Significant (P < 0.001) differences in creatinine concentrations by Roche enzymatic vs Jaffe methods were observed in venipuncture specimens compared with arterial or venous catheter specimens, suggesting dopamine and dobutamine reversibly adhere to the catheter lumen. CONCLUSIONS Negative interferences were pronounced for Roche enzymatic results in blood samples obtained from indwelling catheters, a phenomenon not observed in peripheral draws. Physicians and laboratorians should be alert to the possibility of a falsely low creatinine result and reevaluate questionable samples using a method unaffected by catecholamines.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prime time for enzymatic creatinine methods in pediatrics.

BACKGROUND The literature regarding the nonspecificity of applications of the Jaffe (alkaline picrate) reaction for creatinine is generally outdated. We conducted a specificity study to update the nonspecificity information for current Jaffe and enzymatic creatinine assays. METHODS Two serum pools with creatinine concentrations within the pediatric reference interval were spiked with albumin,...

متن کامل

HPLC with enzymatic detection as a candidate reference method for serum creatinine.

We present a candidate Reference Method for determining the concentration of serum creatinine. The method is based on HPLC combined with enzymatic determination. Creatinine plus 14[C]creatinine is extracted by cation-exchange chromatography, subjected to reversed-phase HPLC, and finally quantified enzymatically. Enzymatic measurement ensures no interference from co-eluting compounds, which has ...

متن کامل

Pseudohypercreatininaemia in two patients caused by monoclonal IgM interference with enzymatic assay of creatinine.

INTRODUCTION Creatinine is released into the blood following non-enzymatic hydrolysis of creatine in skeletal muscle, and excreted into urine depending on glomerular filtration. The serum creatinine concentration is widely used as a marker of glomerular function because it increases in patients with decreased glomerular filtration rate (GFR). Although GFR is costly to measure, an estimated GFR ...

متن کامل

Kinetics of enzymatic O-methylation: its value in assays for catecholamines in plasma.

The kinetics of enzymatic O-methylation of catecholamines were studied under conditions like those used in the radioenzymatic assay of plasma catecholamines. Inappropriate Michaelis-Menten kinetics and linear approximations of exponential equations were not used. Mathematical analysis indicated the importance of the ratio of methyl donor (S-adenosylmethionine) to substrate (catecholamine) conce...

متن کامل

Enzymatic assays for creatinine: time for action.

Estimation of glomerular filtration rate (eGFR) on the basis of serum creatinine concentration measurements using equations is critical to ongoing global public health efforts to improve the diagnosis and treatment of chronic kidney disease. There is now ongoing activity to promote world-wide standardization of methods to measure creatinine concentrations, together with the introduction of a re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 55 9  شماره 

صفحات  -

تاریخ انتشار 2009