Microhardness of glass ionomer cements indicated for the ART technique according to surface protection treatment and storage time.

نویسندگان

  • Luciana Keiko Shintome
  • Marcos Paulo Nagayassu
  • Rebeca Di Nicoló
  • Silvio Issáo Myaki
چکیده

The aim of this study was to assess the microhardness of 5 glass ionomer cements (GIC) - Vidrion R (V, SS White), Fuji IX (F, GC Corp.), Magic Glass ART (MG, Vigodent), Maxxion R (MR, FGM) and ChemFlex (CF, Dentsply) - in the presence or absence of a surface protection treatment, and after different storage periods. For each GIC, 36 test specimens were made, divided into 3 groups according to the surface protection treatment applied - no protection, varnish or nail varnish. The specimens were stored in distilled water for 24 h, 7 and 30 days and the microhardness tests were performed at these times. The data obtained were submitted to the ANOVA for repeated measures and Tukey tests (alpha = 5%). The results revealed that the mean microhardness values of the GICs were, in decreasing order, as follows: F > CF = MR > MG > V; that surface protection was significant for MR, at 24 h, without protection (64.2 + or - 3.6a), protected with GIC varnish (59.6 + or - 3.4b) and protected with nail varnish (62.7 + or - 2.8ab); for F, at 7 days, without protection (97.8 + or - 3.7ab), protected with varnish (95.9 + or - 3.2b) and protected with nail varnish (100.8 + or - 3.4a); and at 30 days, for F, without protection (98.8 + or - 2.6b), protected with varnish (103.3 + or - 4.4a) and protected with nail varnish (101 + or - 4.1ab) and, for V, without protection (46 + or - 1.3b), protected with varnish (49.6 + or - 1.7ab) and protected with nail varnish (51.1 + or - 2.6a). The increase in storage time produced an increase in microhardness. It was concluded that the different GICs, surface protection treatments and storage times could alter the microhardness values.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of N-Vinylcaprolactam Containing Polyacids and Zirconia on Mechanical Properties of Commercial Glass Ionomer Cements

 This study aimed to investigate the impact of N-vinylcaprolactam (NVC) and Nano-sized yttria-stabilized zirconia (YSZ), separately and simultaneously, on the mechanical properties of the commercial glass ionomer cements (GICs). Methods: The NVC is able to ameliorate the mechanical and surface properties of glass ionomers; however, its effect hasn’t been investigated in conjunc...

متن کامل

Microhardness and Wear Resistance of Glass Ionomer Cements Modified by Chitosan and Nano-Hydroxyapatite

Despite the merits of glass ionomer cements (GICs), they suffer from weak mechanical properties such as low wear resistance. In this study, the mechanical properties of GICs after incorporating chitosan and nano-hydroxyapatite was investigated. The samples were prepared in four groups, including non-modified GIGs (NMGIC, n = 5), chitosan incorporated GICs (CHGIC, n = 5), nano-hydroxyapatite inc...

متن کامل

The effect of heat on the mechanical properties of glass ionomer cements.

AIM The objective of this study was to assess the effect of heat application on the mechanical properties of glass ionomer cements. MATERIALS AND METHODS STUDY DESIGN experimental design. The effect of heat on glass ionomer cements during their setting was evaluated by measuring compressive strength, flexural strength and microhardness. Moroever, temperature changes from one surface of the...

متن کامل

Effectiveness of commonly available surface protecting agents in maintaining microhardness of two cements.

OBJECTIVE To estimate the microhardness of glass ionomer cement (vitrofil) and resin modified glass ionomer cement (vitremere) in the presence and absence of different surface protections. STUDY DESIGN An in-vitro experimental study. PLACE AND DURATION OF STUDY The Department of Operative Dentistry, Dr. Ishrat-ul-Ebad Khan Institute of Oral Health Sciences, Dow University of Health Sciences...

متن کامل

Surface roughness of glass ionomer cements indicated for atraumatic restorative treatment (ART).

The purpose of this study was to evaluate the surface roughness of four conventional chemically cured glass ionomer cements (Fuji IX, Ketac Molar, Vidrion R and Vitromolar) commonly used in atraumatic restorative treatment (ART) immediately after material preparation. Twenty specimens of each glass ionomer cement were fabricated and surface roughness was measured after material setting. The spe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Brazilian oral research

دوره 23 4  شماره 

صفحات  -

تاریخ انتشار 2009