Determination of optimal PTV margin for patients receiving CBCT‐guided prostate IMRT: comparative analysis based on CBCT dose calculation with four different margins
نویسندگان
چکیده
Variations in daily setup and rectum/bladder filling lead to uncertainties in the delivery of prostate IMRT. The purpose of this study is to determine the optimal PTV margin for CBCT-guided prostate IMRT based on daily CBCT dose calculations using four different margins. Five patients diagnosed with low-risk prostate cancer were treated with prostate IMRT to 70 Gy in 28 fractions using daily CBCT for image guidance. The prostate CTV and OARs were contoured on all CBCTs. IMRT plans were created using 1 mm, 3 mm, 5 mm, and 7 mm CTV to PTV expansions. For each delivered fraction, dose calculations were generated utilizing the pretreatment CBCT translational shifts performed and dosimetric analysis was performed. One hundred and forty total treatment fractions (CBCT sessions) were evaluated. The planned prostate CTV V100% was 100% for all PTV margins. Based on CBCT analysis, the actual cumulative CTVs V100% were 96.55% ± 2.94%, 99.49% ± 1.36%, 99.98% ± 0.26%, and 99.99% ± 0.05% for 1, 3, 5, and 7 mm uniform PTV margins, respectively. Delivered rectum and bladder doses were different as compared to expected planned doses, with the magnitude of differences increasing with PTV margin. Daily setup variation during prostate IMRT yields differences in the actual vs. expected doses received by the prostate CTV, rectum, and bladder. The magnitude of these differences is significantly affected by the PTV margin utilized. It was found that when daily CBCT was used for soft-tissue alignment of the prostate, a 3 mm PTV margin allowed for CTV to be covered for 99% of cases.
منابع مشابه
Evaluation of different set-up error corrections on dose–volume metrics in prostate IMRT using CBCT images
We investigated the effect of different set-up error corrections on dose-volume metrics in intensity-modulated radiotherapy (IMRT) for prostate cancer under different planning target volume (PTV) margin settings using cone-beam computed tomography (CBCT) images. A total of 30 consecutive patients who underwent IMRT for prostate cancer were retrospectively analysed, and 7-14 CBCT datasets were a...
متن کاملGeographical miss of the prostate during image‐guided radiotherapy with a 6‐mm posterior expansion margin
INTRODUCTION Our department commonly uses a planning target volume (PTV) expansion of 6 mm posterior and 1 cm in all other directions when treating prostate cancer patients with image-guided radiotherapy (IGRT). This study aimed to test the adequacy of this PTV expansion by assessing geographical miss of the prostate on post-treatment cone-beam CT (CBCT) and identify those at risk of geographic...
متن کاملDosimetric and volumetric changes in the rectum and bladder in patients receiving CBCT‐guided prostate IMRT: analysis based on daily CBCT dose calculation
Delivered dose can be calculated by transferring the planned treatment beams onto the daily CBCT. Bladder and rectum volumetric doses were calculated and cor-related to the daily bladder and rectum fullness. Patients for this study underwent hypofractionated prostate IMRT to 70 Gy in 28 fractions. Daily CBCT was utilized for image guidance. A clinically acceptable plan was created using a CTV-t...
متن کاملSuperiority of a soft tissue‐based setup using cone‐beam computed tomography over a bony structure‐based setup in intensity‐modulated radiotherapy for prostate cancer *
The purpose of this study was to test the superiority of a soft tissue-based setup using cone-beam computed tomography (CBCT) to a bony structure-based setup using the ExacTrac system in intensity-modulated radiotherapy (IMRT) for prostate cancer. We studied 20 patients with localized prostate cancer who received IMRT between November 2010 and February 2012. After the initial setup, the pelvic ...
متن کاملDetermining optimal planning target volume and image guidance policy for post-prostatectomy intensity modulated radiotherapy
BACKGROUND There is limited information available on the optimal Planning Target Volume (PTV) expansions and image guidance for post-prostatectomy intensity modulated radiotherapy (PP-IMRT). As the prostate bed does not move in a uniform manner, there is a rationale for anisotropic PTV margins with matching to soft tissue. The aim of this study is to find the combination of PTV expansion and im...