Radiological assessment of chest compression point and achievable compression depth in cardiac patients.

نویسندگان

  • Sverre Nestaas
  • Knut Haakon Stensæth
  • Vigdis Rosseland
  • Jo Kramer-Johansen
چکیده

BACKGROUND Using magnetic resonance imaging (MRI) to relate cardiovascular structures to surface anatomy in a population relevant to cardiac arrest victims, relate the external thoracic anterior-posterior (AP) diameter (APEXTERNAL) and blood-filled structures to recommended chest compression depths, and define an optimal compression point (OCP). METHODS MRI axial scans of referred patients were analysed. We defined origo as the skin surface of the centre of sternum in the internipple line. The blood-filled structures beneath origo were identified and the sum of their inner diameters (APBLOOD) and APEXTERNAL were measured. We defined OCP based on the image with maximum compressible left and right ventricle and where LVOT was not present. We measured the distance from origo to OCP. RESULTS Consecutive patients, mean (SD), age 52 (17) years, 110 (76 %) males, were categorized: cardiac disease (n = 74), aortic disease (n = 13), no findings/study patient (included in another study) (n = 57). The structure LVOT/aortic valve (AV)/aortic root was present in 46 % of patients with cardiac disease vs. 19 % of patients with no findings. APEXTERNAL for males and females was 25 (2) cm and 22 (2) cm, and APBLOOD 6.5 cm (2) and 4.7 cm (2), respectively. Distance from origo to OCP was 32 (11) mm to the left and 16 (21) mm caudally. DISCUSSION LVOT/AV/aortic root was present beneath the origo in almost half the patients with cardiac disease. Recommended chest compression depths exceeded the anterior-posterior diameter of blood-filled structures in more than half of the females. OCP was found 3 cm left of the origo. CONCLUSIONS Based on our study, individualized compression point and depth could be further studied in a prospective, clinical study.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnosis of thromboembolic disease: Combined ventilation perfusion lung scan and compression ultrasonography

The clinical management of pulmonary embolism and deep venous thrombosis of the legs are similar and requires prolonged anticoagulation therapy. The standard diagnostic approach in patients suspected of pulmonary embolism is ventilation-perfusion (V/Q) lung scan and compression ultrasonography to detect deep venous thrombosis. This retrospective study analyzed the role of V/Q lung scan an...

متن کامل

Effectiveness of feedback with a smartwatch for high-quality chest compressions during adult cardiac arrest: A randomized controlled simulation study

Previous studies have demonstrated the potential for using smartwatches with a built-in accelerometer as feedback devices for high-quality chest compression during cardiopulmonary resuscitation. However, to the best of our knowledge, no previous study has reported the effects of this feedback on chest compressions in action. A randomized, parallel controlled study of 40 senior medical students ...

متن کامل

Accuracy of instructor assessment of chest compression quality during simulated resuscitation.

OBJECTIVES The 2010 American Heart Association Guidelines stress the importance of high quality cardiopulmonary resuscitation (CPR) as a predictor of survival from cardiac arrest. However, resuscitation training is often facilitated and evaluated by instructors without access to objective measures of CPR quality. This study aims to determine whether instructors experienced in the area of adult ...

متن کامل

Relationship of blood pressure and flow during CPR to chest compression amplitude: evidence for an effective compression threshold.

This study was conducted to investigate the importance of the depth of chest compression in producing effective cardiopulmonary resuscitation (CPR) in animals, as indicated by cardiac output and mean arterial blood pressure. Cardiac output was measured by a modified indicator dilution technique in 8 anesthetized dogs, 6 to 12 kg body weight, during repeated 2-minute episodes of electrically ind...

متن کامل

Decay in chest compression quality due to fatigue is rare during prolonged advanced life support in a manikin model

BACKGROUND The aim of this study was to measure chest compression decay during simulated advanced life support (ALS) in a cardiac arrest manikin model. METHODS 19 paramedic teams, each consisting of three paramedics, performed ALS for 12 minutes with the same paramedic providing all chest compressions. The patient was a resuscitation manikin found in ventricular fibrillation (VF). The first s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Scandinavian journal of trauma, resuscitation and emergency medicine

دوره 24  شماره 

صفحات  -

تاریخ انتشار 2016