Otologics fully implantable hearing system: Phase I trial 1-year results.
نویسندگان
چکیده
OBJECTIVE To assess the safety of the Otologics fully implantable hearing system after 1 year of use in a Phase I clinical trial. STUDY DESIGN Repeated-measures within-subjects design. SETTING Procedures were performed in a variety of facilities, including a university, military, and private hospital's ambulatory surgical center and outpatient clinical audiologic test facilities. PATIENTS Adult patients with bilateral moderate to severe sensorineural hearing loss. INTERVENTION(S) Surgical insertion of this prosthesis included an atticotomy to expose the incus, securing the transducer to the mastoid bone, attaching the transducer tip to the incus via insertion into a laser-drilled hole, and postauricular implantation of the microphone/battery/electronics capsule. MAIN OUTCOME MEASURE(S) Subjective patient benefit, aided sound field thresholds, and speech discrimination with the subject's own, appropriately fit, walk-in hearing aid(s) and the prosthesis were assessed. RESULTS There were no pre-post-implant differences noted for bone conduction: slight differences were noted in the pre-post-implant air conduction results (p < 0.05). These differences were attributed to the healing process and reversed to almost preimplant assessment levels by the third-month evaluation. Pure-tone averages and monaural word recognition scores were slightly better for the walk-in-aided condition (p < 0.05), whereas the patient benefit scales favored the postoperative implant-aided conditions.Adverse effects of the implant were encountered on 14 occasions after the implantation of the 20 subjects. With the exception of partial device extrusions (that occurred later), all were rectified by the time of initial activation. At the 12-month data collection point, problems that had been encountered by subjects included 1) partial device extrusion (3 subjects), necessitating explantation in 2; 2) loss of external communication (2 subjects), resulting in 1 explantation; and 3) increased charging times beyond 1.5 hours (7), resulting in 3 explantations and 2 patients not using their device while awaiting explantation. CONCLUSION Phase I trial results provide evidence that this fully implantable device can provide sound amplification to sensorineural hearing loss patients, with performance results similar to the patients' walk-in hearing aids.
منابع مشابه
Fully implantable Otologics MET Carina device for the treatment of sensorineural hearing loss. Preliminary surgical and clinical results.
Middle ear implants overcome some of the common problems of conventional hearing aid technology, such as feedback, signal distortion, ear canal occlusion and associated issues. The Otologics MET Carina, Boulder, CO, USA, is a fully implantable hearing prosthesis designed to address the amplification needs of adults (> 18 years of age), with moderate to severe sensorineural hearing loss and norm...
متن کاملLong-Term Patient Satisfaction With Different Middle Ear Hearing Implants in Sensorineural Hearing Loss
Introduction: Implantable hearing devices are a viable option for patients with moderate-to-severe sensorineural hearing loss who cannot benefit from the conventional hearing aids. In this study, we focus on the patients_ satisfaction with 3 different middle ear implants, the Vibrant SoundBridge (VSB), the semiimplantable Otologics MET implant, and the fully implantable Carina implant. Material...
متن کاملFirst bilateral simultaneous implantation with fully implantable middle ear hearing device
The majority of moderate to severe sensorineural hearing loss individuals must rely on amplification of the acoustic signal to improve communication skills. This aim is generally accomplished with conventional air conduction hearing aids [1]. In some cases, hearing aid wearers report difficulties and limited adoption of hearing aids due to ear canal occlusion, pain or irritation of the skin in ...
متن کاملImplantable and Semi-Implantable Hearing Aids: A Review of History, Indications, and Surgery
Introduction The complaints associated with the use of conventional amplifying hearing aids prompted research at several centers worldwide that ultimately led to the development of implantable devices for aural rehabilitation. Objectives To review the history, indications, and surgical aspects of the implantable middle ear hearing devices. Data Synthesis Implantable hearing aids, such as the Vi...
متن کاملدستگاههای کاشتپذیر برای کودکان ناشنوا
The idea of providing hearing to profoundly deaf patients by artificially stimulating the sensory system has progressed from a futuristic possibility to reality. Generally, an implantable hearing device is designed to capture sound and present it to the auditory system, where at least part of the device is surgically implanted in the child receiving it. The goal of the implantable devices in yo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology
دوره 29 4 شماره
صفحات -
تاریخ انتشار 2008