Assessment of Tear Film Optical Quality Dynamics.

نویسندگان

  • A-Yong Yu
  • Ting Lu
  • An-Peng Pan
  • Duo-Ru Lin
  • Chen-Chen Xu
  • Jin-Hai Huang
  • Fang-Jun Bao
چکیده

PURPOSE To investigate tear film optical quality dynamics by analyzing the postblink temporal changes of objective scatter index (OSI). METHODS A total of 109 myopic subjects without symptoms of dry eye and 32 myopic subjects diagnosed with dry eye disease were recruited in this cross-sectional study. The right eye for each subject was analyzed. Serial measurements of OSI were performed for 20 seconds in the interval of 0.5 second using a double-pass instrument, and 10 successive seconds of nonblinking immediately after a blink was selected to analyze the tear film optical quality dynamics. The tear breakup time (TBUT) was also measured. The mean OSI in 10 successive seconds and the correlation coefficient between OSI and time were analyzed. RESULTS For subjects without symptoms of dry eye, 109 eyes were divided into two categories based on the correlation coefficient between OSI and time: category A (without positive correlation) and category B (with positive correlation). Categories A and B were further divided into four categories based on the mean OSI for 10 seconds: category A1 (36.7%, lower than 1.00); category A2 (33.0%, equal to or greater than 1.00); category B1 (13.8%, lower than 1.00), and category B2 (16.5%, equal to or greater than 1.00). Dry eye subjects were set as category C for comparison. There was no significant difference in the TBUT among the five categories (A1, A2, B1, B2, C) except between category C and category A1 (P < 0.01) and category C and category A2 (P < 0.05). CONCLUSIONS Dynamic changes of OSI after blinking showed variations even in clinically asymptomatic subjects, and four categories of tear film were proposed based on the optical quality dynamics. The procedure using serial measurements of OSI as a noninvasive and objective method may have potential applications for detecting preclinical phase of dry eye disease in asymptomatic subjects.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Role of the tear film in the optical quality of the human eye.

This paper reviews recent studies of the role of the tear film in the optical quality of the eye. Recent investigations focus on the dynamics of the tear film after a blink and its important role in the optical quality of the eye. The results in this review were used in an attempt to understand the optical and visual impact of tear-film breakup in normal eyes and dry eyes. It was noted that pat...

متن کامل

Objective optical assessment of tear-film quality dynamics in normal and mildly symptomatic dry eyes.

PURPOSE To evaluate and compare the tear-film dynamics in normal eyes and in eyes with mild dry-eye symptoms using a new noninvasive optical method based on a double-pass instrument. SETTING Hospital Universitario Virgen de la Arrixaca, Murcia, Spain. DESIGN Evaluation of diagnostic test or technology. METHODS Dynamic recording of double-pass retinal images during unforced tear-film break...

متن کامل

Automatic dynamic tear meniscus measurement in optical coherence tomography

An image processing algorithm is developed for quantitative assessment of tear meniscus dynamics from continuous optical coherence tomography (OCT) measurements. Clinical utility of dynamic OCT tear meniscus measurement is assessed in studies of tear meniscus parameters. The results indicate that any apparent changes in the early post-blink phase meniscus parameters are essentially related to t...

متن کامل

Changes in aberrations and retinal image quality due to tear film dynamics.

A reliable and objective method to measure aberration changes due to the tear film is essential in improving clinical assessment of the tear film and in vivo retinal imaging. The tear film of 11 subjects are studied by acquiring continuous wavefront measurements in real-time with a customized Shack-Hartmann wavefront sensor. The device has a high resolution lenslet array (190 mum) and a topogra...

متن کامل

The importance of the precorneal tear film for the quality of optical imaging.

The optical function of the eye critically depends on the presence of an intact precorneal tear film. Abnormalities of the tear film such as those occurring in the dry eye syndrome or in otherwise irritated eyes may interfere with vision. In 30 patients with dry eyes artificial tears were found to produce statistically significant improvement of vision (p less than 0.001) while no significant c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 57 8  شماره 

صفحات  -

تاریخ انتشار 2016