Assay of vitamins D2 and D3, and 25-hydroxyvitamins D2 and D3 in human plasma by high-performance liquid chromatography.

نویسنده

  • G Jones
چکیده

I describe a new assay that is capable of measuring vitamin D2, vitamin D3, 25-hydroxyvitamin D2, and 25-hydroxyvitamin D3 in 2 ml of plasma or serum. Plasma is extracted by the Bligh and Dyer technique [Can. J. Biochem. Physiol. 37, 911 (1959)], the lipid component is fractionated by two high-performance liquid-chromatographic systems based upon adsorption and reversed-phase chromatography, and each of the four vitamin D metabolites is measured by its absorbance at 254 nm. The method has a sensitivity limit of 0.5 mug/liter of plasma. The identity of metabolite peaks was confirmed by mass spectrometry, ultraviolet absorption spectrophotometry, and rechromatography, and there was good correlation (r=0.84) between plasma 25-hydroxyvitamin D as measured by the present method and by a protein binding assay developed in our laboratory. Mean concentrations of vitamin D and 25-hydroxyvitamin D in normal adults (n=25) in December were 2.2 +/- 1.1 (SD) and 16 +/- 3.9 (SD) mug/liter, respectively. 25-Hyroxyvitamin D2 made up 31% of the total 25-hydroxyvitamin D. Patients receiving pharmacological doses of vitamin D had values for vitamin D and 25-hydroxyvitamin D that were 10- to 100-fold normal. This method provides a rapid, reliable physico-chemical assay that appears to have advantages over existing protein binding assays and can be used to measure circulating vitamin D.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assay for plasma 25-hydroxyvitamin D2 and 25-hydroxyvitamin D3 by "high-performance" liquid chromatography.

We describe a new, rapid, and simple column-chromatographic procedure for 25-OH vitamin D3 in plasma. The vitamin is extracted by use of Sep-pak C18 (octadecyl alkylated silicic acid), a short factory-packed reversed-phase column, and 25-OH vitamin D2 + 25-OH vitamin D3 fraction is eluted with methanol/water. The 25-OH D2 and 25-OH D3 are then well resolved on a high-resolution 3-micrometer sil...

متن کامل

High-performance liquid chromatographic assay for 25-hydroxyvitamin D3 in serum.

We describe a precise and specific method for measuring 25-hydroxyvitamin D3 in 1 ml of human serum. Extraction with chloroform/methanol followed by chromatography on a 0.5 X 2-cm silica gel column yields a sample that is sufficiently free of extraneous material for high-performance liquid chromatography on a column of microporous silica gel (10 micron average particle diameter). The measuremen...

متن کامل

Determination of vitamins A, D and E in a small volume of human plasma by a high-throughput method based on liquid chromatography/tandem mass spectrometry.

We have developed an automated high-throughput assay for the determination of vitamin A (retinol), ergocalciferol (25-OH D2), cholecalciferol (25-OH D3) and vitamin E (α-tocopherol) in a small volume of human plasma. Sample preparation involved mixing 50 μL of plasma with 100 μL of ethanol containing isotope-labelled internal standards, followed by mixing with isooctane/chloroform (3:1, 300 μL)...

متن کامل

Differential effects of vitamin D2 and D3 supplements on 25-hydroxyvitamin D level are dose, sex, and time dependent: a randomized controlled trial

BACKGROUND Vitamin D (D) supplements are indispensable for its world-wide deficiency. Controversy continues on ergocalciferol (D2) and cholecalciferol (D3) relative potency as well as on dosing-schedule and sex role in raising 25-hydroxy D (25(OH)D) level, the best indicator of D status. METHODS We randomized 279 adults to daily D2, D3, D2/D3, or placebo; 2-weekly D2 or D3; or 4-weekly D2 or ...

متن کامل

Application of ultra-high-performance liquid chromatography/tandem mass spectrometry for the measurement of vitamin D in infant formula and adult/pediatric nutritional formula: First Action 2011.11.

In an effort to measure vitamin D, ultra-high-performance liquid chromatography with tandem mass spectrometry (UHPLC-MS/MS) was applied to samples. The use of UHPLC-MS/MS decreased the run time by 50%. The UHPLC-MS/MS achieved equal or better separation efficiency with complex food matrixes compared to HPLC-MS/MS. It was also observed that under the optimized conditions of UHPLC, all previtamin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 24 2  شماره 

صفحات  -