Ultrasound method applied to characterize healthy femoral diaphysis of Wistar rats in vivo

نویسندگان

  • A. Fontes-Pereira
  • D.P. Matusin
  • P. Rosa
  • A. Schanaider
  • M.A. von Krüger
  • W.C.A. Pereira
چکیده

A simple experimental protocol applying a quantitative ultrasound (QUS) pulse-echo technique was used to measure the acoustic parameters of healthy femoral diaphyses of Wistar rats in vivo. Five quantitative parameters [apparent integrated backscatter (AIB), frequency slope of apparent backscatter (FSAB), time slope of apparent backscatter (TSAB), integrated reflection coefficient (IRC), and frequency slope of integrated reflection (FSIR)] were calculated using the echoes from cortical and trabecular bone in the femurs of 14 Wistar rats. Signal acquisition was performed three times in each rat, with the ultrasound signal acquired along the femur's central region from three positions 1 mm apart from each other. The parameters estimated for the three positions were averaged to represent the femur diaphysis. The results showed that AIB, FSAB, TSAB, and IRC values were statistically similar, but the FSIR values from Experiments 1 and 3 were different. Furthermore, Pearson's correlation coefficient showed, in general, strong correlations among the parameters. The proposed protocol and calculated parameters demonstrated the potential to characterize the femur diaphysis of rats in vivo. The results are relevant because rats have a bone structure very similar to humans, and thus are an important step toward preclinical trials and subsequent application of QUS in humans.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of treadmill running on femoral bone in young orchidectomized rats.

Forty 6-wk-old male Wistar rats weighing 308 +/- 24 g were divided into two groups. On day 0, the 20 animals in one group were surgically castrated and the other group was sham operated. Within each group, 10 rats were selected for treadmill running (60% maximal O2 consumption, 1 h/day, 6 days/wk for 15 wk). The 20 sedentary rats were used as controls. At the time the rats were killed (day 105)...

متن کامل

A Rare Case of Neonatal Birth with Congenital Bilateral Femoral Deficiency Undetected in Prenatal Ultrasound

Background:Prenatal ultrasound plays an important role in the early and accurate evaluation of the congenital skeletal and non-skeletal abnormalities of the fetus and is effective in predicting pregnancy outcomes. Congenital femoral deficiency (CFD) is a rare complicated and non-hereditary anomaly that includes the hypoplasia of a portion of the femoral bone with shortening the lower limb. Cas...

متن کامل

Comparative effects of alendronate and alfacalcidol on cancellous and cortical bone mass and bone mechanical properties in ovariectomized rats.

The purpose of the present study was to compare the effects of alendronate and alfacalcidol on cancellous and cortical bone mass and bone mechanical properties in ovariectomized rats. Twenty-six female Sprague-Dawley rats, 7 months of age, were randomized by the stratified weight method into four groups: the sham-operated control (Sham) group and the three ovariectomy (OVX) groups, namely, OVX ...

متن کامل

Histomorphometric assessment of bone necrosis produced by two cryosurgery protocols using liquid nitrogen: an experimental study on rat femurs

OBJECTIVE The aim of this study was to evaluate the effects of liquid nitrogen cryosurgery on the femoral diaphysis of rats. MATERIAL AND METHODS The femoral diaphyses of 42 Wistar rats were exposed to three local and sequential applications of liquid nitrogen for 1 or 2 min, intercalated with periods of 5 min of passive thawing. The animals were sacrificed after 1, 2, 4 and 12 weeks and the ...

متن کامل

Use of Ultrasonic Parameters as Adjuvant Tool of Diagnosis and Monitoring of Bone Lesions

Ultrasound parameters were proposed to characterize femur in vitro from rats. Six quantitative parameters (Apparent Integrated Ultrasonic Backscatter AIB, Frequency Slope of Apparent Backscatter – FSAB, Temporal Slope Apparent Backscatter TSAB, Integrated Reflection Coefficient IRC, Slope and Frequency Integrated Reflection FSIR and Temporal Slope Reflection Coefficient TSRC) were applied to th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 47  شماره 

صفحات  -

تاریخ انتشار 2014