Comparison of Spectra Optia and COBE Spectra apheresis systems' performances for red blood cell exchange procedures.
نویسندگان
چکیده
BACKGROUND Spectra Optia (Terumo BCT, Lakewood, CO) was FDA approved for red blood cell exchange (RBCx) procedures in January 2014 and is expected to replace COBE spectra (Terumo BCT) very soon in the USA. The performance characteristics of these devices for Isovolemic Hemodilution (IHD-RBCx) procedure were compared in this study. METHODS A total of 114 IHD-RBCx procedures from 19 patients were analyzed. For every patient, three procedures on each device with similar pre-procedure hematocrits were compared. Pre and post procedure laboratory parameters compared were hemoglobin S (HbS), hematocrits (Hct), platelet counts and fraction of cells remaining (FCR). Statistical analysis was performed using t-test adjusted by the Holm-Bonferroni method to reduce family-wise error rate. RESULTS There were no significant differences between these two devices in regards to HbS, Hct, FCR and platelet counts (p = > 0.05). However, rinseback volume (124.2 ± 8.9 ml) and normal saline replacement volume during IHD phase (296.1 ± 97.2 ml) were lower in Spectra Optia as compared to COBE Spectra (337 ± 33.8 ml and 326.6 ± 105.2 ml, p value <0.001 and 0.030 respectively). Spectra Optia had a longer run time (107.1 ± 15.9 min vs 123.8 ± 19.6 min, p value <0.001) overall. CONCLUSIONS Performance characteristics of Spectra Optia for HbS, Hct and FCR were similar to COBE Spectra for IHD-RBCx. IHD-RBCx procedure on Optia required less normal saline replacement volume and rinse back volume but with overall longer procedure run time.
منابع مشابه
Comparison of Two Apheresis Systems of COBE and Optia for Autologous Peripheral Blood Stem Cell Collection
Peripheral blood stem cell (PBSC) transplantation following myeloablative therapy is a mainstay of treatment for various types of malignancies. This study aimed to evaluate the differences between the Optia MNC and COBE Spectra MNC systems (Terumo BCT, Japan) according to apheresis procedures and the parameters of apheresis, products, and collection. The clinical data of 74 patients who underwe...
متن کاملTherapeutic Plasma Exchange Using the Spectra Optia Cell Separator Compared With the COBE Spectra
BACKGROUND The Spectra Optia (SPO) is a novel continuous-flow centrifugal apheresis system based on the COBE Spectra (CSP) platform. There have been few attempts to validate the advantages of the SPO. We performed a retrospective study comparing the two cell separators for therapeutic plasma exchange (TPE) procedures in kidney transplant (KT) patients and seeing efficacy and safety. METHODS W...
متن کاملSpectra Optia® for Automated Red Blood Cell Exchange in Patients with Sickle Cell Disease: A NICE Medical Technology Guidance
The Spectra Optia® automated apheresis system, indicated for red blood cell exchange in people with sickle cell disease, underwent evaluation by the National Institute for Health and Care Excellence, which uses its Medical Technologies Advisory Committee to make recommendations. The company (Terumo Medical Corporation) produced a submission making a case for adoption of its technology, which wa...
متن کاملIron depletion with a novel apheresis system in patients with hemochromatosis.
BACKGROUND Phlebotomy represents the standard treatment option for iron overload in hemochromatosis (HC). Recently, red blood cell (RBC) apheresis has increasingly been used to remove iron. In this study we evaluated the depletion program of the newly developed Spectra Optia device. STUDY DESIGN AND METHODS Adult male patients (n = 11) with HC were RBC depleted with the Spectra Optia device (...
متن کاملTechnical comparison of four different extracorporeal photopheresis systems.
BACKGROUND Extracorporeal photopheresis (ECP) is a therapeutic technique that combines leukapheresis and ultraviolet (UV)A irradiation of the leukapheresate after 8-methoxypsoralen treatment with subsequent retransfusion. It can be achieved with a single device (online) or by combining an apheresis machine with a separate UVA light source (offline). The comparability of both established methods...