Clinical evaluation of a new electronic spirometer.

نویسندگان

  • P Cox
  • L Miller
  • T L Petty
چکیده

An electronic spirometer which utllizee a thermistor end an linearizing circuit, was evaluated. When compared to a Collins 13.5 liter water seal spirometer, 60 test results from 30 patienls revealed no clinically significant difference in forced vital capacity (FVC), forced expiratory volume in one second (FEVih or maximum voluntary ventilation (MVV). The device was found durable Pnd highly usefd in the hospital or cllnic.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application and Evaluation of Portable Field Instruments for Measuring Forced Expiratory Volume of Children and Adults in Environmental Health Surveys

In support of Health Effects Research Studies, pulmonary function tests are periodically administered to a large number of children. The ventilatory performance of these children is being evaluated by measuring the 0.75-sec forced expiratory volume (FEV(0.75)) with a waterless mechanical volume spirometer used in conjunction with an electronic timing unit. During a 1-yr testing period, operatio...

متن کامل

Evaluation of a new electronic spirometer: the vitalograph "Escort" spirometer.

BACKGROUND The "Escort" spirometer is a lightweight, hand held spirometer employing a Fleisch pneumotachograph. Measurements of forced expiratory volume in one second (FEV1), forced vital capacity (FVC), and peak expiratory flow (PEF) are obtained from a single FVC manoeuvre. Results are displayed on a small liquid crystal display, but there is no graphical display. The performance of the Escor...

متن کامل

Design, Implementation and Evaluation of Electronic Teaching of Practical and Theoretical Histology Courses: a New Experience at Isfahan University of Medical Science

Introduction: Electronic education system using advanced and varied technology tries to improve quality of teaching-learning process. This research aimed to design and implement the new electronic teaching system in histology courses (theoretical and practical) at the Isfahan University of Medical Sciences. Methods: This action research was conducted in department of anatomy and molecular biol...

متن کامل

Evaluation of a method of estimating the basal metabolic rate.

While the patient is breathing normally into the spirometer he is instructed to make a deep expiration. It is important to ensure the maximal possible emptying of the lung so that all the reserve (supplemental) air will be expelled into the spirometer. To achieve this the subject must be stimulated to go on expelling air until the expiratory line flattens out. This process is repeated once or t...

متن کامل

Evaluation of the turbine pocket spirometer.

A compact electronic spirometer, the turbine pocket spirometer, which measures the FEV1, forced vital capacity (FVC), and peak expiratory flow (PEF) in a single expiration, was compared with the Vitalograph and the Wright peak flow meter in 99 subjects (FEV1 range 0.40-5.50 litres; FVC 0.58-6.48 l; PEF 40-650 l min-1). The mean differences between the machines were small--0.05 l for FEV1, 0.05 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 63 4  شماره 

صفحات  -

تاریخ انتشار 1973