INfluence of interposed ventilation pressure upon artificial cardiac output during cardiopulmonary resuscitation in dogs.

نویسندگان

  • C F Babbs
  • W D Voorhees
  • K R Fitzgerald
  • H R Holmes
  • L A Geddes
چکیده

This study was conducted to determine the effects of high pressure interposed ventilations during cardiopulmonary resuscitation (CPR). Cardiac output was measured by a modified indicator dilution technique in eight anesthetized, intubated mongrel dogs. Positive pressure ventilations (12/min, 80% O2) were interposed after every five chest compressions (performed at 62/min) by a mechanical chest compressor (Thumper). On repeated trials in the same animal, ventilation pressures from 10--50 cm of H2O were tested in randomized sequence, while the technique of chest compression was held constant. Arterial blood gases immediately after resuscitation were monitored. Increasing ventilation pressure had surprisingly little effect on cardiac output curing CPR, although blood gases were profoundly altered. For ventilation pressures of 10, 20, 30, 40, and 50 cm of H2O, producing mean tidal volumes 23, 38, 61, 83, and 94 ml/kg; cardiac output remained nearly constant, averaging 21, 25, 23, 26, and 24 ml/min . kg. Corresponding mean postresuscitation pH was 7.24, 7.41, 7.51, 7.56, and 7.53; PCO2 was 41, 26, 18, 16, and 15 torr. The postresuscitation arterial oxygen tension was greater than 100 torr at all ventilation pressures except 10 cm of H2O. Interposed ventilations of pressure and volume more than adequate to prevent acidosis during CPR did not impair artificial cardiac output. If anything, cardiac output was slightly improved by more forceful ventilation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cardiopulmonary resuscitation with interposed abdominal compression in dogs.

This study was conducted to evaluate the hemodynamic effectiveness of a new modification of cardiopulmonary resuscitation (CPR), termed interposed abdominal compression-CPR (IAC-CPR). IAC-CPR utilizes all the steps of standard CPR with the addition of abdominal compressions interposed during the release phase of chest compression. Ventricular fibrillation was induced electrically in 10 anesthet...

متن کامل

Improved oxygen delivery during cardiopulmonary resuscitation with interposed abdominal compressions.

The ability of a new modification of cardiopulmonary resuscitation (CPR) to deliver oxygen to tissues was evaluated. The method utilizes standard CPR techniques with the addition of manual abdominal compressions (congruent to 100 mm Hg) interposed between chest compressions, and is termed interposed abdominal compression-CPR (IAC-CPR). Oxygen delivery was measured by a spirometer in a closed ci...

متن کامل

Regional blood flow during cardiopulmonary resuscitation in dogs using simultaneous and nonsimultaneous compression and ventilation.

We studied regional blood flow (QR) using radiolabeled microspheres and measured hemodynamic variables in 20 anesthetized dogs in normal sinus rhythm and during ventricular fibrillation treated with cardiopulmonary resuscitation (CPR). Nonsimultaneous compression and ventilation CPR (NSCV-CPR) was performed in seven dogs with a pneumatic piston that gave 50 chest compressions/min with an open a...

متن کامل

ORIGINAL ARTICLES Regional Blood Flow During Cardiopulmonary Resuscitation in Dogs Using Simultaneous and Nonsimultaneous Compression and Ventilation

We studied regional blood flow (QR) using radiolabeled microspheres and measured hemodynamic variables in 20 anesthetized dogs in normal sinus rhythm and during ventricular fibrillation treated with cardiopulmonary resuscitation (CPR). Nonsimultaneous compression and ventilation CPR (NSCV-CPR) was performed in seven dogs with a pneumatic piston that gave 50 chest compressions/min with an open a...

متن کامل

Influence of adrenergic drugs upon vital organ perfusion during CPR.

To determine whether adrenergic drugs administered during CPR alter the distribution of artificial cardiac output, the authors measured regional blood flow and cardiac output using radioactive microspheres in 12 dogs. Ventricular fibrillation was induced electrically and CPR was immediately begun with a mechanical chest compressor and ventilator (Thumper) at 60 compressions/min, with a ventilat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Critical care medicine

دوره 8 3  شماره 

صفحات  -