Forces and moments generated by removable thermoplastic aligners.

نویسنده

  • Hung V Vu
چکیده

INTRODUCTION The exact force systems as well as their progressions generated by removable thermoplastic appliances have not been investigated. Thus, the purposes of this experimental study were to quantify the forces and moments delivered by a single aligner and a series of aligners (Invisalign; Align Technology, Santa Clara, Calif) and to investigate the influence of attachments and power ridges on the force transfer. METHODS We studied 970 aligners of the Invisalign system (60 series of aligners). The aligners came from 30 consecutive patients, of which 3 tooth movements (incisor torque, premolar derotation, molar distalization) with 20 movements each were analyzed. The 3 movement groups were subdivided so that 10 movements were supported with an attachment and 10 were not. The patients' ClinCheck (Align Technology, Santa Clara, Calif) was planned so that the movements to be investigated were performed in isolation in the respective quadrant. Resin replicas of the patients' intraoral situation before the start of the investigated movement were taken and mounted in a biomechanical measurement system. An aligner was put on the model, the force systems were measured, and the calculated movements were experimentally performed until no further forces or moments were generated. Subsequently, the next aligners were installed, and the measurements were repeated. RESULTS The initial mean moments were about 7.3 N·mm for maxillary incisor torque and about 1.0 N for distalization. Significant differences in the generated moments were measured in the premolar derotation group, whether they were supported with an attachment (8.8 N·mm) or not (1.2 N·mm). All measurements showed an exponential force change. CONCLUSIONS Apart from a few maximal initial force systems, the forces and moments generated by aligners of the Invisalign system are within the range of orthodontic forces. The force change is exponential while a patient is wearing removable thermoplastic appliances.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High Force Levels Can Be Delivered With Thermoplastic Aligners Initial Forces Generated by Three Types of Thermoplastic Appliances on an Upper Central Incisor During Tipping

Background: Treatment of minor malocclusions with clear thermoplastic aligners is more commonly being used as an aesthetic alternative to fixed appliances. This can be done by manually resetting teeth on a plaster model or by models generated from a 3D computer model (Invisalign®). However, little research has been performed on the complex force systems generated by these types of appliances. O...

متن کامل

Changes in force associated with the amount of aligner activation and lingual bodily movement of the maxillary central incisor

OBJECTIVE The purposes of this study were to measure the orthodontic forces generated by thermoplastic aligners and investigate the possible influences of different activations for lingual bodily movements on orthodontic forces, and their attenuation. METHODS Thermoplastic material of 1.0-mm in thickness was used to manufacture aligners for 0.2, 0.3, 0.4, 0.5, and 0.6 mm activations for lingu...

متن کامل

Removable thermoplastic appliances modified by incisal cuts show altered biomechanical properties during tipping of a maxillary central incisor

BACKGROUND The present study aimed to evaluate the force delivery of removable thermoplastic appliances (RTAs), modified by different sized incisal cuts, during tipping of a maxillary central incisor in palatal and vestibular direction. METHODS Forty-five RTAs from three different materials (Biolon®, Erkodur®, Ideal Clear®) of the same thickness (1 mm) were used. Analysis was performed on a s...

متن کامل

Effectiveness of Composite Attachments in Controlling Upper-Molar Movement with Aligners.

of accuracy of upper-molar bodily movement with aligners when a distalization movement of at least 1.5mm was prescribed, attributing any significant difference to the use of attachments.6 These observations were made in the horizontal plane; tipping effects were not analyzed. Tipping movements are difficult to control during molar distalization with aligners because of the trays’ limited contac...

متن کامل

Chewing efficiency and occlusal forces in PMMA, acetal and polyamide removable partial denture wearers.

PURPOSE Thermoplastic materials, such as acetal (AC) and polyamide (PA), constitute an alternative to polymethyl methacrylate (PMMA) based resins as the materials for removable partial dentures. However, none of the previous studies compared chewing efficiency and occlusal forces in the wearers of dentures made of various materials. Therefore, the aim of this study was to determine and compare ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics

دوره 146 5  شماره 

صفحات  -

تاریخ انتشار 2014