Steady state visual evoked potential (SSVEP) based brain-computer interface (BCI) performance under different perturbations

نویسندگان

  • Zafer İşcan
  • Vadim V Nikulin
چکیده

Brain-computer interface (BCI) paradigms are usually tested when environmental and biological artifacts are intentionally avoided. In this study, we deliberately introduced different perturbations in order to test the robustness of a steady state visual evoked potential (SSVEP) based BCI. Specifically we investigated to what extent a drop in performance is related to the degraded quality of EEG signals or rather due to increased cognitive load. In the online tasks, subjects focused on one of the four circles and gave feedback on the correctness of the classification under four conditions randomized across subjects: Control (no perturbation), Speaking (counting loudly and repeatedly from one to ten), Thinking (mentally counting repeatedly from one to ten), and Listening (listening to verbal counting from one to ten). Decision tree, Naïve Bayes and K-Nearest Neighbor classifiers were used to evaluate the classification performance using features generated by canonical correlation analysis. During the online condition, Speaking and Thinking decreased moderately the mean classification accuracy compared to Control condition whereas there was no significant difference between Listening and Control conditions across subjects. The performances were sensitive to the classification method and to the perturbation conditions. We have not observed significant artifacts in EEG during perturbations in the frequency range of interest except in theta band. Therefore we concluded that the drop in the performance is likely to have a cognitive origin. During the Listening condition relative alpha power in a broad area including central and temporal regions primarily over the left hemisphere correlated negatively with the performance thus most likely indicating active suppression of the distracting presentation of the playback. This is the first study that systematically evaluates the effects of natural artifacts (i.e. mental, verbal and audio perturbations) on SSVEP-based BCIs. The results can be used to improve individual classification performance taking into account effects of perturbations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Steady State Visual Evoked Potential (SSVEP) - based Brain Spelling System with Synchronous and Asynchronous Typing Modes

The paper presents an EEG-based wireless brain-computer interface (BCI) with which subjects can mindspell text on a computer screen. The application is based on detecting steady-state visual evoked potentials (SSVEP) in EEG signals recorded on the scalp of the subject. The performance of the BCI is compared for two different classification paradigms: synchronous and asynchronous modes.

متن کامل

New Paradigms for Brain Computer Interface Based on SSVEP

A Brain Computer Interface (BCI) creates a new communication channels for disabled peoples, the classical way of steady-state visual evoked potential (SSVEP) based on (BCI) was focusing on multi-frequency and phases. In this study a novel high-speed SSVEP based on BCI, was implemented a new paradigms of SSVEP, which induced by irregular flickering with phase-tagged toward brain activity respons...

متن کامل

A Survey of Stimulation Methods Used in SSVEP-Based BCIs

Brain-computer interface (BCI) systems based on the steady-state visual evoked potential (SSVEP) provide higher information throughput and require shorter training than BCI systems using other brain signals. To elicit an SSVEP, a repetitive visual stimulus (RVS) has to be presented to the user. The RVS can be rendered on a computer screen by alternating graphical patterns, or with external ligh...

متن کامل

SSVEP Based BCI for an Object Control in 2D Space

The Brain-Computer Interfaces can successfully help the healthy and disabled users, in performing various activities in their day to day life. But still such high expectations are yet to be fulfilled by the existing BCI designs due to their restricted reliability and less understanding of the brain mechanisms used in it. Brain-computer interface (BCI) systems based on the steady-state visual ev...

متن کامل

Enhancement of SSVEP-based BCI system via SSAEP during Eye Fatigue Period

This paper proposes the auditory evoked potential (SSAEP) stimulation technique as well as its detection algorithm to replace the steady state visual evoked potential (SSVEP)-based brain-computer interface (BCI) system during the visual fatigue period. Optimal speaker position for two commands SSAEP-based BCI system and the possible electrode positions are investigated. With the proposed system...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2018