Some advantages of transesophageal echocardiography during mitral valve replacement.

نویسندگان

  • K Orihashi
  • Y Matsuura
  • H Ishihara
  • Y Hamanaka
  • Y Kawaue
  • T Sueda
  • K Kanehiro
  • T Nomimura
چکیده

Transesophageal echocardiography (TEE) was conducted during mitral valve replacement (MVR) in six cases. Two-dimensional echocardiography demonstrated the prosthetic valve as an ovalshaped, echogenic ring and highly echogenic disc which showed rhythmical to-and-fro movement. Using two-dimensional color Doppler echocardiography (2D-CD-TEE), the regurgitant flow was demonstrated as the toward flow looked like a flame. 2D-CD-TEE made it possible to determine the regurgitant site from the origin of the flame. In most cases the regurgitant site was located just inside of the ring, thus suggesting intentionally designed transvalvular leak. In one case, however, the regurgitant site was just outside of the ring which suggested pathological paravalvular leak. But we could not find any evidence of mitral regurgitation on the left atrial pressure tracing or necropsy 20 days after the operation. 2D-CD-TEE is considered sensitive in detecting mitral regurgitation and an provide much information during the operation without interrupting the surgical procedures or interference by the operation. Additionally it can determine the pathological paravalvular leak from functional transvalvular leak.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Right sided heart evaluation after successful mitral valve replacement.

Introduction: It is well-documented that right-sided heart dysfunction and significant tricuspid valve regurgitation (TVR) have adverse effects on patient outcomes after left-sided heart valve surgery. Therefore, the evaluation of right ventriclular (RV) function and TR severity in patients who had undergone mitral valve replacement (MVR), associated with/without concomitant su...

متن کامل

Evaluation of transesophageal echocardiography in detecting cardiac sources of emboli in ischemic stroke patients

  Background: Embolus is one of the causes of ischemic stroke that can be due to cardiac sources such as valvular heart diseases and atrial fibrillation and atheroma of the aorta. Transesophageal echocardiography (TEE) is superior in identifying potential cardiac sources of emboli. Due to insufficient data on TEE findings in ischemic stroke in Iran, the present study was done to evaluate TEE in...

متن کامل

Distortion of Aortic Valve from Mechanical Traction Imposed by the Mitral Valve Prosthesis: The Three-dimensional Transesophageal Echocardiographic Perception

Iatrogenic injury to the aortic valve is a rare but frequently reported complication during mitral valve surgeries. Intraoperative 2-dimensional transesophageal echocardiography (2D TEE) has a major impact in diagnosing these injuries, so that timely intervention is possible. However, 2D TEE has lot of limitations during the perioperative period, which can be overcome by the three dimensional e...

متن کامل

Cardiac Valve Prostheses

To determine the value of transesophageal ultrasound in the assessment of cardiac valve prostheses, 14 patients with clinically suspected mitral prosthesis malfunction were studied by transthoracic and transesophageal two-dimensional imaging as well as by color Doppler flow velocity mapping (color Doppler). Patients underwent left ventricular angiography (n = 13), surgery (n =11), or both angio...

متن کامل

Case Report: Anterolateral Papillary Muscle Rupture Caused by Brucella Endocarditis

Introduction: Brucellosis is a common zoonosis in Iran, transmitted to humans by direct contact with infected animal materials like fleece, animal excrement, leather, butchery or by the consumption of contaminated animal products (e.g. fresh cheese, unpasteurized milk or dairy products, and raw meat and raw liver that is consumed semi-roasted by kebab sellers in Iran. Case Presentation: A 21-ye...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Hiroshima journal of medical sciences

دوره 37 3  شماره 

صفحات  -

تاریخ انتشار 1988