Well storage effect during pumping tests in an aquifer of low permeability
نویسندگان
چکیده
Abstract Well storage effect is generally considered while interpreting pumping test data from large diameter wells. However, in an aquifer of low permeability, the well storage is found to be significant during pumping tests conducted on bore wells. The interpretation of such data gives ambiguous results unless well storage effect is taken into account. A field example is presented to illustrate the difficulty in interpretation of the pumping test data. In order to take into account the well storage effect, a finite difference approach of interpreting pumping test data is suggested.
منابع مشابه
تغییر ضرایب ذخیره و قابلیت انتقال آبخوان دشت الشتر بهعلت خشکسالی و افزایش بهرهبرداری منابع آب زیرزمینی
Drought and overexploitation of groundwater should control the aquifer properties (e.g. storage coefficient and transmisivity). The role of stress factors is identified when the performance of aquifer hydrodynamic coefficients be studied. Since in the most aquifers, allocation and utilization management is based on the pumping test in the past, it would not be expected the optimal management. I...
متن کاملInvestigation of Underground Gas Storage in a Partially Depleted Naturally Fractured Gas Reservoir
In this work, studies of underground gas storage (UGS) were performed on a partially depleted, naturally fractured gas reservoir through compositional simulation. Reservoir dynamic model was calibrated by history matching of about 20 years of researvoir production. Effects of fracture parameters, i.e. fracture shape factor, fracture permeability and porosity were studied. Results show...
متن کاملAirflow induced by pumping tests in unconfined aquifer with a low-permeability cap
[1] Most analytical and numerical models developed to analyze pumping test data focus on saturated flow below the water table. Traditionally the soil above the initial water table prior to pumping has been thought to have little influence on the test results and has usually been ignored. It is hypothesized that, if the unsaturated zone is capped by low-permeability soil, airflow in the unsatura...
متن کاملA Numerical Investigation into the Effect of Controllable Parameters on the Natural Gas Storage in a Weak Reservoir-type Aquifer
Natural gas storage process in aquifer, due to fluid flow behavior of gas and water in the porous medium and because of their contact with each other under reservoir conditions, faces several challenges. Therefore, there should be a clear understanding of the injected gas behavior before and after the injection into the reservoir. This research simulates the natural gas storage in aquifer by us...
متن کاملCharacterization of aquifer heterogeneity using transient hydraulic tomography
[1] Hydraulic tomography is a cost-effective technique for characterizing the heterogeneity of hydraulic parameters in the subsurface. During hydraulic tomography surveys a large number of hydraulic heads (i.e., aquifer responses) are collected from a series of pumping or injection tests in an aquifer. These responses are then used to interpret the spatial distribution of hydraulic parameters o...
متن کامل