Localization of Abnormal Conduction Pathways for Tachyarrhythmia Treatment Using Tagged MRI

نویسندگان

  • Gerardo I. Sanchez-Ortiz
  • Maxime Sermesant
  • Kawal S. Rhode
  • Raghavendra Chandrashekara
  • Reza Razavi
  • Derek L. G. Hill
  • Daniel Rueckert
چکیده

Tachyarrhythmias are pathological fast heart rhythms often caused by abnormally conducting myocardial areas (foci). Treatment by radio-frequency (RF) ablation uses electrode-catheters to monitor and destroy foci. The procedure is normally guided with x-rays (2D), and thus prone to errors in location and excessive radiation exposure. Our main goal is to provide pre- and intra-operative 3D MR guidance in XMR systems by locating the abnormal conduction pathways. We address the inverse electro-mechanical relation by using motion in order to infer electrical propagation. For this purpose we define a probabilistic measure of the onset of regional myocardial activation, derived from 3D motion fields obtained by tracking tagged MR sequences with non-rigid registration. Activation isochrones are then derived to determine activation onset. We also compare regional motion between two different image acquisitions, thus assisting in diagnosing arrhythmia, in follow up of treatment, and in determining whether the ablation was successful. Difference maps of isochrones and other motion descriptors are computed to determine abnormal patterns. Validation was carried out using an electromechanical model of the heart, synthetic data, a cardiac MRI atlas of motion and geometry, MRI data from 6 healthy volunteers (one of them subjected to stress), and an MRI study on a patient with tachyarrhythmia, before and after RF ablation. A pre-operative MRI study on a second patient with tachyarrhythmia was used to test the methodology in a clinical scenario, predicting the abnormally conducting region.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measuring myocardial motion changes in tagged MR to establish inverse electro-mechanical coupling for XMR-guided RF ablation

Radio-frequency (RF) ablation uses electrode-catheters to destroy abnormally conducting myocardial areas that lead to potentially lethal tachyarrhythmias. The procedure is normally guided with x-rays (2D), leading to errors in location and excessive radiation exposure. One of our goals is to provide preand intra-operative 3D MR guidance in XMR systems (combined X-ray and MRI room) by locating m...

متن کامل

The effect of incorporating the quantitative analysis besides visual assessments of 18F-FDG brain PET images for the localization of epileptogenic zones

Introduction: FDG Brain PET is a valuable paraclinical tool for presurgical assessments of patients suffering from refractory epilepsy. By the widespread accessibility of PET, recognizing the functional lesions has become a current practical method especially in preoperative evaluations of the partial epilepsy disorders. The aim of our study was to assess the impact of quantit...

متن کامل

Effects Of Fast Pathway Ablation On The Concealment Zone And Electrophysiological Behavior Of AV-Node During Atrial Fibrillation.

Objectives: Dual pathways have a determinant role in the occurrence of atrio nodal tachyarrhythmia (AVNRT). The aim of present study is to determine the role of slow pathway (SP) in the concealment zone and protective role of AV node during atrial fibrillation (AF). Material &Methods: In 7 isolated nodal rabbit preparation zone of concealment and concealed conduction is quantified by Specif...

متن کامل

Mouse Heart Rate in a Human: Diagnostic Mystery of an Extreme Tachyarrhythmia

We report telemetry recording of an extreme non-fatal tachyarrhythmia noted in a hospitalized quadriplegic male with history of atrial fibrillation where the average ventricular conduction rate was found to be about 600 beats per minute and was associated with transient syncope. A medical literature review suggests that the fastest human ventricular conduction rate reported to date in a tachyar...

متن کامل

Fetal tachyarrhythmia with 1:1 atrioventricular conduction. Adenosine infusion in the umbilical vein as a diagnostic test.

This is the report of a case of fetal tachyarrhythmia with 1:1 atrioventricular conduction detected by pre-natal echocardiography in a fetus at 25-weeks gestation. Adenosine infusion via cordocentesis was performed as a diagnostic test to differentiate between atrioventricular nodal reentrant supraventricular tachyarrhythmia and atrial flutter. After infusion, transient 2:1 atrioventricular dis...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention

دوره 8 Pt 1  شماره 

صفحات  -

تاریخ انتشار 2005