Lucigenin chemiluminescence assay for superoxide detection.
نویسنده
چکیده
Superoxide Detection To the Editor: The recent review by Tarpey and Fridovich published in Circulation Research1 mostly contains interesting and sound material; however, I would like to comment on the section entitled, “Superoxide Detection, Chemiluminescence Reactions.” Basing mainly on their own data,2 authors maintain that lucigenin-amplified chemiluminescence (LucCL) overestimates the rate of superoxide production due to the redox cycling of lucigenin. Taking into account that LucCL is the most sensitive method of superoxide detection, which is especially useful for the detection of low superoxide concentrations in vascular systems (see, for example, References 3 through 5), such an assertion (if true) devalues numerous previous experimental findings. Fortunately, it is not true. And our conclusion is not due to “the triumph of hope over reality”1 (page 229) but is based on reliable experimental data. We have shown earlier6 that lucigenin cannot take part in redox cycling with molecular oxygen because of its positive one-electron reduction potential (about 0.19 V). (Spasojevic et al7 recently measured the two-electron reduction potential of lucigenin as 0.14 V. However, it was shown long ago that two-electron reduction potentials are not equal to one-electron reduction potentials.8) In addition to theoretical considerations, it is possible to demonstrate the reliability of the LucCL method on the basis of experimental data. We9 compared the results of superoxide measurement by LucCL and cytochrome c reduction in several enzymatic and cellular systems, and we found out that there are excellent correlations among the results obtained for the xanthineand NADH-xanthine oxidase systems, neutrophils, and monocytes (correlation coefficients are of 0.930 to 0.994). More than that, we showed that if the direct reduction of lucigenin takes place (for example, in NADH-xanthine oxidase system), it will result in a decrease, and not an increase, in superoxide production due to the competition between one-electron reduction of oxygen and lucigenin. Hence, we believe that lucigenin-amplified chemiluminescence remains a reliable and sound assay of superoxide detection.
منابع مشابه
Chemiluminescent detection of oxidants in vascular tissue. Lucigenin but not coelenterazine enhances superoxide formation.
Lucigenin-amplified chemiluminescence has frequently been used to assess the formation of superoxide in vascular tissues. However, the ability of lucigenin to undergo redox cycling in purified enzyme-substrate mixtures has raised questions concerning the use of lucigenin as an appropriate probe for the measurement of superoxide production. Addition of lucigenin to reaction mixtures of xanthine ...
متن کاملEvaluation of chemiluminescence reagents for selective detection of reactive oxygen species.
In order to evaluate the chemiluminescence (CL) reagents for selective detection of reactive oxygen species (ROS), we comprehensively measured the CL responses of 20 CL reagents (three luminol derivatives, two imidazopyrazinone derivatives, eight lophine derivatives, six acridinium ester derivatives and lucigenin) against six types of ROS (superoxide anion: O(2)(*-), hydroxyl radical: *OH, hydr...
متن کاملInvestigation of alveolar macrophage function using lucigenin-dependent chemiluminescence.
The method using lucigenin-dependent phagocytic chemiluminescence is described for the assessment of alveolar macrophage metabolic activity in response to stimulation by opsonised particles or soluble agents. The requirement for superoxide anion (O2-) in the production of chemiluminescence is suggested by inhibition (95%) using superoxide dismutase. The results obtained are correlated with thos...
متن کاملA simple chemiluminescence method for measuring oxygen-derived free radicals generated in oxygenated rat myocardium.
We have developed a simple and reproducible method employing chemiluminescence to measure oxygen-derived free radicals generated in oxygenated myocardium. Isolated perfused rat hearts were frozen in liquid nitrogen during the control perfusion (non-ischemia), after 30 min of global ischemia (ischemia), or after 20 min of reperfusion following 30-min global ischemia (reperfusion). The frozen hea...
متن کاملThe generation of lucigenin chemiluminescence from the reaction of guanidino compounds with phenylglyoxal under alkaline conditions and its application.
It is shown that o-carboxyphenylglyoxal, which is converted from ninhydrin by alkali, produces a chemiluminescent lucigenin reaction under alkaline conditions when with reacted with guanidino compounds. It is also demonstrated that phenylglyoxal, which is a model compound of o-carboxyphenylglyoxal, produces a strong chemiluminescent lucigenin reaction under alkaline conditions when reacted with...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation research
دوره 89 11 شماره
صفحات -
تاریخ انتشار 2001