Dosimetric effects of anatomical changes during fractionated photon radiation therapy in pancreatic cancer patients
نویسندگان
چکیده
Pancreatic tumors show large interfractional position variation. In addition, changes in gastrointestinal gas volumes and body contour take place over the course of radiation therapy. We aimed to quantify the effect of these anatomical changes on target dose coverage, for the clinically used fiducial marker-based patient position verification and, for comparison, also for simulated bony anatomy-based position verification. Nine consecutive patients were included in this retrospective study. To enable fraction dose calculations on cone-beam CT (CBCT), the planning CT was deformably registered to each CBCT (13-15 per patient); gas volumes visible on CBCT were copied to the deformed CT. Fraction doses were calculated for the clinically used 10 MV VMAT treatment plan (with for the planning target volume (PTV): D98% = 95%), according to fiducial marker-based and bony anatomy-based image registrations. Dose distributions were rigidly summed to yield the accumulated dose. To evaluate target dose coverage, we defined an iCTV+5 mm volume, i.e., the internal clinical target volume (iCTV) expanded with a 5 mm margin to account for remaining uncertainties including delineation uncertainties. We analyzed D98% , Dmean , and D2% for iCTV+5 mm and PTV (i.e., iCTV plus 10 mm margin). We found that for fiducial marker-based registration, differences between fraction doses and planned dose were minimal. For bony anatomy-based registration, fraction doses differed considerably, resulting in large differences between planned and accumulated dose for some patients, up to a decrease in D98% of the iCTV+5 mm from 95.9% to 85.8%. Our study shows that fractionated photon irradiation of pancreatic tumors is robust against variations in body contour and gastrointestinal gas, with dose coverage only mildly affected. However, as a result of interfractional tumor position variations, target dose coverage can severely decline when using bony anatomy for patient position verification. Therefore, the use of intratumoral fiducial marker-based daily position verification is essential in pancreatic cancer patients.
منابع مشابه
Investigate Change Cardiac Perfusion Pattern Following By Hypo-fractionated and Conventional Radiation Therapy Schedule in Patients with Left-Sided Breast Cancer
Introduction: Radiation-induced cardiovascular damage is a potential side effect of radiation therapy in patients with left-sided breast cancer. This prospective study compares the severity and reversibility of perfusion and functional abnormalities before, and six months after, 3D-Conformal radiation therapy treatment in left-side breast cancer patients with conventional and h...
متن کاملDosimetric Evaluation of Target Volume in Breast Boost Radiotherapy: Comparison of Electron and Photon Beam
Background and purpose: Breast‑conserving surgery followed by radiation therapy to the whole breast is now recognized as a standard strategy in patients with breast cancer. Recommended technique for radiotherapy is whole breast irradiation followed by boost to the tumor bed. This study aimed to compare the dosimetric parameters of electron and photon beams for boosting irradiation in post‑lump...
متن کاملAnalysis of Hip Joint Dose in Prostate Cancer Radiation Therapy: A Dosimetric Comparison of Treatment Plans
Background and purpose: Radiation therapy as a part of cancer treatment is used in almost 50-60% of involved cases. In prostate cancer radiation therapy, a large volume of pelvis is irradiated, so, it is necessary to preserve sensitive organs around the treatment area, especially rectum and bladder. In this study, some dosimetric parameters such as minimum dose (Dmin), maximum dose (Dmax), mean...
متن کاملDosimetric Comparison of 3D Tangential Radiotherapy of Post-Lumpectomy Breast at Two Different Energies
Introduction: Radiation therapy following breast conserving surgery is one of the most common procedures performed in any radiation oncology department. A tangential parallel-opposed pair is almost always the technique of choice for this purpose. This technique is often performed based on 3D treatment planning. The aim of this study was to compare 3D treatment planning for two different energie...
متن کاملEvaluating the effects of esophageal and breast cancer radiotherapy on the cardiac function and determining the relationship between the dosimetric parameters and ejection fraction changes
Background: In the radiotherapy of patients with esophagus and breast cancer, the heart receives a significant dose of radiation that might cause heart complications. Thefore, the aim of the current study was to evaluate the effects of esophagus and left breast cancer radiotherapy on the cardiac function and to determine the relationship between the dosimetric parameters and ejection fraction (...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 18 شماره
صفحات -
تاریخ انتشار 2017