Letter by Pfeiffer et al Regarding Article, "Early Structural Valve Deterioration of Mitroflow Aortic Bioprosthesis: Mode, Incidence, and Impact on Outcome in a Large Cohort of Patients".

نویسندگان

  • Steffen Pfeiffer
  • Theodor Fischlein
  • Giuseppe Santarpino
چکیده

BACKGROUND Structural valve deterioration (SVD) is a major flaw of bioprostheses. Early SVD has been suspected in the last models of Mitroflow bioprosthesis. We sought to assess the incidence, mode, and impact of SVD on outcome in a large series of Mitroflow aortic valve replacement. METHODS AND RESULTS Six hundred seventeen consecutive patients (aged 76.1±6.3 years) underwent aortic valve replacement with a Mitroflow prosthesis (models 12A/LX) between 2002 and 2007. By echocardiography, 39 patients developed early SVD (1.66% per patient-year), with stenosis as the main mode (n=36). Mean delay to SVD was only 3.8±1.4 years, and 5-year SVD-free survival was 91.6% (95% confidence interval [CI], 88.7-94.7) for the whole cohort and 79.8% (95% CI, 71.2-89.4) and 94.0% (95% CI, 90.3-97.8) for 19- and 21-mm sizes, respectively. Among the 39 patients with SVD, 13 patients (33%) had an accelerated SVD once the mean gradient exceeded 30 mm Hg. Valve-related death was 46.2% in this SVD subgroup. Five-year overall survival was 69.6% (95% CI, 65.7-73.9). In multivariable analysis, SVD was the strongest correlate of overall mortality (hazard ratio=7.7; 95% CI, 4.4-13.6). CONCLUSIONS Early SVD is frequent in Mitroflow bioprosthesis (models 12A/LX), especially for small sizes (19 and 21 mm), and reduces overall survival. An unpredictable accelerated pattern of SVD constitutes a life-threatening condition. In view of the large number of Mitroflow valves implanted worldwide, one can expect an epidemic of SVD and valve-related deaths, which represents a major public health issue, especially in the elderly. Hence, a close follow-up with yearly echocardiography after Mitroflow implantation is advisable. An urgent reoperation should be discussed in patients with severe SVD even though they are still asymptomatic.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Early Structural Valve Deterioration of Mitroflow Aortic Bioprosthesis: Mode, Incidence and Impact on Outcome in a Large Cohort of Patients

Dept of Thoracic and CardioVascular Surgery, University Hospital, Nantes, France; Institut du Thorax, University Hospital, Nantes, France; Member of Translink European Network (dedicated to structural valve deterioration); Dept of Cardiology, University Hospital, Nantes, France; Inserm UMR1087, Nantes, France; Dept of Statistic-EA 4275, University of Medicine, Nantes, France; Dept of Radiology ...

متن کامل

Early Structural Valve Deterioration of the Mitroflow Aortic Bioprosthesis: Will the New Anticalcification Treatment Change Anything?

T here has been a trend toward more frequent use of biopros-thetic valves, especially in the young generations, over the last decade. 1 Freedom from warfa-rin use and restrictions on diet and activities make bioprosthetic valves more attractive and popular, and multiple reports have shown that choosing a bioprosthetic valve does not decrease survival despite the increased rate of reoperation. T...

متن کامل

Structural deterioration of the Freestyle aortic valve: mode of presentation and mechanisms.

BACKGROUND Structural valve deterioration is the major cause of bioprosthetic valve failure. Because of the unique design features and anti-calcification treatment of the Freestyle (Medtronic Inc, Minneapolis, Minn) stentless bioprosthesis, development of structural valve deterioration may differ in comparison with other bioprosthetic valves. This study evaluates the mechanisms and clinical pre...

متن کامل

Neo Left Main Channel Creation Using Double Stenting Alongside a Sapien 3 Aortic Valve Bioprosthesis for Left Main Coronary Obstruction Following Valve-in-Valve Transcatheter Aortic Valve Replacement: A Case Report With Review of Literature

Transcatheter aortic valve replacement in the setting of failed surgical bioprosthesis (valve-in-valve) is a valuable option for patients with bioprosthetic aortic stenosis or regurgitation who are deemed high risk for repeat open heart surgery. Although the procedure is successful with proper preprocedural assessment, instances of left main (LM) coronary artery ostium obstruction have been doc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 132 12  شماره 

صفحات  -

تاریخ انتشار 2014