Robot-assisted 13 MHz epicardial ultrasound for endoscopic quality assessment of coronary anastomoses.

نویسندگان

  • Ricardo P J Budde
  • Thomas C Dessing
  • Rudy Meijer
  • Patricia F A Bakker
  • Cornelius Borst
  • Paul F Gründeman
چکیده

In totally endoscopic coronary artery bypass surgery, intra-operative assessment of anastomotic quality is needed. We evaluated the endoscopic application of epicardial ultrasound to visualize the coronary anastomosis and detect a construction error. In 8 pigs (71-78kg), 16 internal mammary artery to left anterior descending coronary artery anastomoses were constructed conventionally, either correctly (n=8) or incorrectly with a suture cross-over construction error (n=8). A 13MHz mini-transducer (15x9x6mm) was introduced through a port and manipulated by the 'da Vinci' system. The chest was re-opened and scanning repeated manually. Postoperatively, macroscopic inspection served as reference and the intra-operative ultrasound images were scored as 'correct' or 'construction error' by two blinded observers. All anastomoses were scored accurately by both observers. One anastomosis constructed to be correct was scored as construction error, due to narrowing of the outflow corner and anastomotic orifice. Ultrasound images corresponded with macroscopic inspection. Closed-chest scan time was about 1.5 times longer than open-chest scan time, 176s (88-464) (median, range) versus 125s (75-314) (P=0.01), respectively. Closed-chest epicardial 13MHz ultrasound scanning required a median of 3min and enabled discrimination between correctly and incorrectly constructed coronary anastomoses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Robot-Assisted Epicardial Ultrasound for Coronary Artery Localization and Anastomosis Quality Assessment in Totally Endoscopic Coronary Bypass Surgery

Coronary artery bypass grafting (CABG) is a routine procedure, traditionally performed via median sternotomy access on the arrested heart with use of cardiopulmonary bypass (onpump). It is the clinical gold standard for myocardial revascularization in patients with multivessel coronary heart disease but remains associated with significant morbidity and mortality (Borst & Gründeman, 1999). Over ...

متن کامل

Geometry assessment of coronary artery anastomoses with construction errors by epicardial ultrasound.

OBJECTIVE There is concern about the quality of the distal anastomosis in off-pump coronary artery bypass grafting. We investigated the impact of specific construction errors on anastomotic geometry using epicardial ultrasound. METHODS Twelve ex vivo pressure perfused porcine and five isolated post-mortem human hearts were used to construct 35 internal mammary artery to coronary artery anasto...

متن کامل

Intraoperative color Doppler ultrasound assessment of LIMA-to-LAD anastomoses in off-pump coronary artery bypass grafting.

BACKGROUND Although techniques for off-pump coronary artery bypass grafting (CABG) are continually being refined, angiographic follow-up studies have indicated a higher rate of anastomoses-related stenoses than expected after traditional on-pump CABG. This study was performed to evaluate the use of intraoperative epicardial color Doppler ultrasound to quality-assess left internal mammary artery...

متن کامل

Quality of computer enhanced totally endoscopic coronary bypass graft anastomosis--comparison to conventional technique.

OBJECTIVE Aims of the study were to develop an endoscopic technique to perform robot assisted coronary anastomoses, using a computer enhanced telemanipulator and to compare the quality of the anastomoses with those performed using a standard open technique. METHODS A surgical telemanipulator with two instrument arms and a central videoscopic arm was used to perform remote endoscopic coronary ...

متن کامل

Detection of internal thoracic artery dissection at coronary anastomosis using intraoperative 15-MHz high-frequency epicardial ultrasound.

A 66-year-old man with a history of diabetes mellitus presented with angina pectoris with 3-vessel disease, and he underwent off-pump coronary artery bypass grafting via median sternotomy. After performing bypass grafting of the left internal thoracic artery to the left anterior descending artery, the appearance of anastomosis configuration appeared to be acceptable. However, transit time flow ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Interactive cardiovascular and thoracic surgery

دوره 3 4  شماره 

صفحات  -

تاریخ انتشار 2004