Direct measurement of thermal fluctuation of high-Q pendulum.
نویسندگان
چکیده
We have achieved a direct measurement of the thermal fluctuation of a pendulum in an off-resonant and wide frequency region using a laser interferometric gravitational-wave detector. These measurements have been well identified for over one decade by an agreement with a theoretical prediction, which is derived by a fluctuation-dissipation theorem. Thermal fluctuation was dominated by the contribution of resistances in coil-magnet actuator circuits. When we tuned these resistances, the noise spectrum also changed according to a theoretical prediction. The measured thermal noise level corresponds to a high quality factor on the order of 10(5) of the pendulum.
منابع مشابه
On determining G using a cryogenic torsion pendulum
A measurement of G which will use a torsion pendulum in the ‘dynamic’ (time-of-swing) mode, measuring the influence of field source masses on the pendulum’s oscillation period, is being prepared at UC Irvine. Features of the design include: (i) operation at cryogenic temperature (2 K) to reduce thermal noise and increase frequency stability and for ease of magnetic shielding, (ii) large pendulu...
متن کاملAn Inverted-Pendulum Thrust Stand for High-Power Electric Thrusters∗
The inverted-pendulum method of thrust measurement for high-power electric thrusters is described analytically and experimentally. Two sources of uncertainty in the thrust measurements are investigated: those due to changes in the sensitivity of the inverted pendulum and those due to tare forces resulting from thermal stresses and electromagnetic forces acting on the flexural elements. An ideal...
متن کاملTorsion pendulum facility for direct force measurements of LISA GRS related disturbances
A four mass torsion pendulum facility for testing of the LISA GRS is under development in Trento. With a LISA-like test mass suspended off-axis with respect to the pendulum fiber, the facility allows for a direct measurement of surface force disturbances arising in the GRS. We present here results with a prototype pendulum integrated with very large-gap sensors, which allows an estimate of the ...
متن کاملWeak Force Measurement in Bistable Optomechanical System
One of the main milestones in the study of opto-mechanical system is to increase the sensitivity of weak forces measurement up to the standard quantum limit. We have studied the detection of weak force under a bistable condition in red detuned regime. In this case, dynamics of the system behaves asymptotically similar to stationary state and applying external force affects phase and fluctuation...
متن کاملDirect observation of large temperature fluctuations during DNA thermal denaturation.
In this Letter, we report direct measurement of large low frequency temperature fluctuations in double stranded DNA when it undergoes a denaturation transition. The fluctuation, which occurs only in the temperature range where the denaturation occurs, is several orders more than the expected equilibrium fluctuation. It is absent in single stranded DNA of the same sequence. The fluctuation at a ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physical review letters
دوره 104 4 شماره
صفحات -
تاریخ انتشار 2010