Multiresidue determination of pesticides in drinking and related waters by gas chromatography/mass spectrometry after solid-phase extraction: interlaboratory study.
نویسندگان
چکیده
As part of a project funded by the European Commission (EC) for the development and evaluation of multiresidue methods for analysis of drinking and related waters, 15 European laboratories evaluated a method using styrene-divinylbenzene co-polymer solid-phase extraction followed by gas chromatography/mass spectrometry. The main aim of the study was to evaluate whether the method meets the requirements of EC Directive 98/83 in terms of accuracy, precision, and detection limit for 22 pesticides according to the following requirements: limit of detection, < or = 0.025 microg/L; accuracy, expressed as recovery between 75 and 125%; and precision, expressed as repeatability relative standard deviation of the method of < 12.5% and as reproducibility relative standard deviation of the method of < 25%. Analyses for unknown concentrations were performed with fortified commercial bottled and tap waters. All laboratories were able to achieve detection limits of 0.01 microg/L for all pesticides except dimethoate and desisopropylatrazine (0.02 microg/L). The criteria for repeatability were met for all compounds except trifluralin, dimethoate, and lindane in bottled water and chlorpyrifos, dimethoate, and lindane in tap water. The criteria for reproducibility were met for all compounds except trifluralin, dimethoate, and lindane in bottled water and pendimethalin, chlorpyrifos, dimethoate, terbutryn, and lindane in tap water. In terms of accuracy, the method meets the requirements for all pesticides in both matrixes, except for lindane in bottled water and lindane and chlorpyrifos in tap water.
منابع مشابه
Multiresidue determination of organophosphorus pesticides in corn oil using solid-phase extraction with lanthanum silicate sorbent and gas chromatography
Phosalone, malathion and diazinon were analyzed in corn oil using solid phase extraction (SPE)with lanthanum silicate as a new solid sorbent followed by gas chromatography with nitrogenphosphorus detection (GC-NPD). The efficiency of different eluents (methanol, dichloromethane,ethyl acetate, dichloromethane — ethyl acetate (1:1) and ethyl acetate — methanol (1:1)) werecompared for elution of o...
متن کاملON-LINE SOLID-PHASE EXTRACTION AND LIQUID CHROMATOGRAPHY/PARTICLE BEAM-MASS SPECTROMETRY FOR DEGRADATION STUDIES OF SOME POLAR PESTICIDES IN WATER
An on-line automated method for photodegradation studies of isoproturon, diuron, atrazine, fenitrothion, and metoxuron by means of liquid chromatography/mass spectrometry (LC/MS) with particle beam (PB) interface is described. Surface water samples were first spiked with 50 µg/l of each pesticide and then exposed to the radiation of the medium-pressure mercury lamp. Next, in regular intervals o...
متن کاملDetermination of Some Selected Pesticide Residues in Apple Juice by Solid - Phase Microextraction Coupled to Gas Chromatography – Mass Spectrometry
HERCEGOVÁ, A., MŐDER, M.: Determination of some selected pesticide residues in apple juice by solid-phase microextraction coupled to gas chromatography – mass spectrometry. Acta univ. agric. et silvic. Mendel. Brun., 2011, LIX, No. 1, pp. 121–128 The performance of solid phase microextraction (SPME) for enrichment of pesticides from apple juice was investigated. Samples were diluted with water,...
متن کاملNew monitoring system for ninety pesticides and related compounds in river water by solid-phase extraction with determination by gas chromatography/mass spectrometry.
A new monitoring system was established for the determination of 90 pesticides and 10 pesticide degradation products in river water. The pesticides consisted of 18 fungicides, 30 insecticides, and 42 herbicides. The pesticides were extracted with a solid-phase, styrene-divinylbenzene copolymer, eluted with acetone, hexane, and ethyl acetate, and determined by gas chromatography/mass spectrometr...
متن کاملAn On-Line Solid Phase Extraction-Liquid Chromatography-Tandem Mass Spectrometry Method for the Determination of Perfluoroalkyl Acids in Drinking and Surface Waters
An UHPLC-MS/MS multiresidue method based on an on-line solid phase extraction (SPE) procedure was developed for the simultaneous determination of 9 perfluorinated carboxylates (from 4 to 12 carbon atoms) and 3 perfluorinated sulphonates (from 4 to 8 carbon atoms). This work proposes using an on-line solid phase extraction before chromatographic separation and analysis to replace traditional met...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of AOAC International
دوره 84 5 شماره
صفحات -
تاریخ انتشار 2001