A study of partial pressure of arterial carbon dioxide and end-tidal carbon dioxide correlation in intraoperative and postoperative period in neurosurgical patients

نویسندگان

  • Pallavi Gaur
  • Minal Harde
  • Pinakin Gujjar
  • Devanand Deosarkar
  • Rakesh Bhadade
چکیده

BACKGROUND AND AIM Monitoring carbon dioxide (CO2) is of utmost importance in neurosurgical patients. It is measured by partial pressure of arterial CO2 (PaCO2) and end-tidal CO2 (ETCO2). We aimed to study the correlation between PaCO2 and ETCO2 in neurosurgical patients in the intraoperative and postoperative period on mechanical ventilation in Postanesthesia Care Unit (PACU). METHODOLOGY This was prospective observational study done at tertiary care teaching public hospital over a period of 1 year. We studied 30 patients undergoing elective craniotomy intraoperatively and in the postoperative period on mechanical ventilation for 24 h. Serial measurement of ETCO2 and PaCO2 at baseline, hourly intraoperatively and every 6 hourly in the PACU were studied. Data analysis was done using SPSS software version 20. RESULTS The mean PaCO2-ETCO2 gradient intraoperatively over 4 h is 3.331 ± 2.856 and postoperatively over 24 h is 2.779 ± 2.932 and lies in 95% confidence interval. There was statistically significant correlation between PaCO2 and ETCO2 intraoperatively baseline, 1 h, 2 h, 3 h, and 4 h with Pearson's correlation coefficients of 0.799, 0.522, 0582, 0.439, and 0.547, respectively (P < 0.05). In PACU at baseline, 6 h, 12 h, 18 h, and 24 h Pearson's correlation coefficients were. 534, -0.032, 0.522, 0.242, 0.592, and 0.547, respectively, which are highly significant at three instances (P < 0.01). CONCLUSION ETCO2 correlates PaCO2 with acceptable accuracy in neurosurgical patients in the intraoperative and postoperative period on mechanical ventilation in Intensive Care Unit. Thus, continuous and noninvasive ETCO2 can be used as a reliable guide to estimate arterial PCO2 during neurosurgical procedures and in PACU.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigating the Relationship Between End Tidal Carbon Dioxide and Arterial Carbon Dioxide Pressure in Patients With Respiratory Distress Referred to the Emergency Room of Hazrat Rasool Akram Hospital

Background: Measuring End-Tidal Carbon Dioxide (ETCO-2) can be a non-invasive, fast, and reliable method to predict partial pressure of carbon dioxide (PaCO2) in patients with respiratory distress. This method, which can be a suitable substitute to measure PaCO2, is being used in many emergency rooms and operating rooms in developed countries, but its exact relationship with PaCO2 has not been ...

متن کامل

End-tidal Carbon Dioxide Measurements in Unintentional Non-Fire-Related Carbon Monoxide Poisoning

Background: Poisoning with carbon monoxide occurs occasionally worldwide, and the gold diagnostic standard is to measure carboxyhemoglobin level in the blood. This study investigated the correlation between carboxyhemoglobin and the end-tidal carbon dioxide levels in 50 patients with carbon monoxide poisoning. Methods: We recruited 50 volunteer patients who had been admitted to the Emergency S...

متن کامل

بررسی همبستگی و میزان توافق نتایج PaCO2 گازهای خون شریانی با CO2 انتهای بازدمی (End-Tidal CO2) توسط کاپنوگرافی در بیماران مبتلا به تشدید حاد بیماری انسدادی ریوی (COPD)

  Background : Chronic Obstructive Pulmonary Disease (COPD) represents a major public health problem. The course of COPD is characterized by episodic periods of worsening symptoms, termed exacerbations. Supplemental oxygen should be given to patients with COPD exacerbation without causing CO2 retention. Arterial blood gas sampling is the gold standard for monitoring adequate oxygenation and for...

متن کامل

Standardization and Validation of Non-invasive Monitoring of End Tidal Carbon Dioxide in Neonates via Nasal Cannula: An Observational Study

Background: Carbon dioxide (CO2) is a by-product of cellular metabolism, which could be considered as a reflection of metabolism, circulation, and ventilation. Arterial blood gas analysis (ABG) is the gold standard of monitoring for CO2. However, is an expensive method leading to blood loss and iatrogenic anemia. In addition, each sample is only a...

متن کامل

Concordance between side-stream end-tidal carbon dioxide and arterial carbon dioxide partial pressure in respiratory service setting.

OBJECTIVE To explore the correlation and concordance between end-tidal carbon dioxide and arterial carbon dioxide partial pressure, and confirm the experience of the general consensus among service environments. DESIGN A prospective cross-sectional analysis. SETTING Two respiratory service units in Hong Kong. PARTICIPANTS Two hundred respiratory patients were recruited, in whom 219 sets o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017