Evaluation of pressure changes in a new design tracheal tube cuff, the Portex Soft Seal, during nitrous oxide anaesthesia.

نویسندگان

  • B al-Shaikh
  • M Jones
  • F Baldwin
چکیده

We have measured pressure changes in a newly designed tracheal tube cuff, the Portex Soft Seal, during nitrous oxide anaesthesia compared with a Mallinckrodt Lo-Contour tube and a Portex Profile tube. The pressure increases in both control groups were significantly greater than those with the new design (P < 0.0001 in each case). The mean increase in pressure in the Mallinckrodt Lo-Contour tube cuff was 9.9 (SD 3.4) mm Hg compared with 10.3 (1.8) mm Hg in the Portex Profile tube cuff and 2.1 (1.5) mm Hg in the Portex Soft Seal tube cuff. We conclude that the Portex Soft Seal cuff prevented a significant increase in intracuff pressure during nitrous oxide anaesthesia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sore throat after operation: influence of tracheal intubation, intracuff pressure and type of cuff.

One hundred and eighty-four patients were studied to elucidate the contribution of intracuff pressure and cuff type to the occurrence of sore throat and hoarseness after operation. The patients were allocated to one of the following groups: A = mask only; B = reusable Rüsch tube with intermittent cuff volume adjustment; C = reusable Rüsch tube without cuff volume adjustment; D = disposable Port...

متن کامل

Effects of nitrous oxide and oxygen on tracheal tube cuff gas volumes.

The changes in the volume of the cuffs of 200 air-inflated tracheal tubes were studied on exposure to 70% nitrous oxide and 30% oxygen. The length of the cuff, its diameter, wall thickness and residual volume were measured. Increases in the volume of gas occurred in all tubes in a time-dependent manner. The tracheal tubes with low-pressure cuffs were more permeable to nitrous oxide and oxygen t...

متن کامل

Compliance characteristics of the Portex Soft Seal Cuff improves seal against leakage of fluid in a pig trachea model

BACKGROUND The Portex Soft Seal high-volume, low-pressure cuffed tracheal tube was compared with the Mallinckrodt HiLo, Sheridan Preformed and Portex Profile tracheal tubes for leakage of dye placed in the subglottic space of a pig's trachea which was used in a benchtop mechanical ventilation model and in six isolated pig tracheas. RESULTS There was no leakage, either in the ventilation model...

متن کامل

Tracheal tube and laryngeal mask cuff pressure during anaesthesia - mandatory monitoring is in need

BACKGROUND To prevent endothelium and nerve lesions, tracheal tube and laryngeal mask cuff pressure is to be maintained at a low level and yet be high enough to secure air sealing. METHOD In a prospective quality-control study, 201 patients undergoing surgery during anaesthesia (without the use of nitrous oxide) were included for determination of the cuff pressure of the tracheal tubes and la...

متن کامل

[Effects of tracheal tube cuff limit pressure (25 cmH2O) and "seal" pressure on tracheal mucosa of dogs.].

BACKGROUND AND OBJECTIVES Injuries of tracheal mucosa in contact with tracheal tube cuff is a function of cuff pressure and exposure time. This study aimed at analyzing injuries of tracheal mucosa in contact with tracheal tube cuff inflated to reach "seal" pressure or limit 25 cmH2O pressure, below critical 30 cmH2O, to prevent tracheal damage. METHODS This study involved 16 dogs submitted to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 83 5  شماره 

صفحات  -

تاریخ انتشار 1999