Comparison of Peristat Online Perimetry with the Humphrey Perimetry in a Clinic-Based Setting
نویسندگان
چکیده
PURPOSE We determined the receiver operating characteristic (ROC) curves for Peristat online perimetry at detecting varying degrees of glaucoma and the correlation between Peristat online perimetry and Humphrey visual field. METHODS A prospective, comparative study of Peristat online perimetry (an achromatic static computer threshold testing program) and Humphrey visual field (HVF) 24-2 SITA standard testing was performed by 63 glaucoma patients and 30 healthy controls in random order. The number of total adjacent abnormal test points were identified for each test, and compared with Spearman correlation. Receive operating characteristic curves were generated for Peristat online perimetry detection of mild and moderate-severe glaucoma patients using contrast sensitivity thresholds of -16.7, -21.7, and -26.7 dB. RESULTS The area under the ROC curve for glaucoma detection ranged from 0.77 to 0.81 for mild disease (mean deviation [MD], >-6 dB on HVF) and 0.85 to 0.87 for moderate to severe disease (MD, <-6 dB on HVF) depending on contrast threshold. Peristat online perimetry and Humphrey visual field abnormal points were highly correlated with Spearman rank correlations ranging from 0.55 to 0.77 (all P < 0.001). CONCLUSIONS Peristat online perimetry exhibits a reasonable ROC curve without specialized equipment and exhibited significant correlation with the conventional 24° Humphrey visual field test. TRANSLATIONAL RELEVANCE Low cost widely available internet-based visual fields may complement traditional office-based visual field testing.
منابع مشابه
Clinical comparison of frequency doubling technology perimetry and Humphrey perimetry.
AIM To determine the number of missed points on frequency doubling technology (FDT) perimetry that optimise the sensitivity and specificity of the test and to determine the topographical accuracy of the test in a clinical setting. METHODS In a prospective study, the perimetric data from 99 patients who underwent both FDT perimetry in the screening mode and Humphrey 24-2 (H24-2) were used to d...
متن کاملA comparison of Goldmann and Humphrey automated perimetry in patients with glaucoma.
Humphrey automated threshold perimetry (Program 30-2) was performed on 42 eyes of 25 patients with glaucoma to determine both the sensitivity and specificity of automated perimetry in detecting glaucomatous visual field defects. Automated perimetry sensitivity was 90.38%, while automated perimetry specificity was 91%. Fifty-two patients and a technician took part in a survey to determine their ...
متن کاملComparison of Octopus Semi-Automated Kinetic Perimetry and Humphrey Peripheral Static Perimetry in Neuro-Ophthalmic Cases
Aim. To compare semikinetic perimetry (SKP) on Octopus 900 perimetry to a peripheral static programme with Humphrey automated perimetry. Methods. Prospective cross-section study comparing Humphrey full field (FF) 120 two zone programme to a screening protocol for SKP on Octopus perimetry. Results were independently graded for presence/absence of field defect plus type and location of defect. Re...
متن کاملComparison of Damato campimetry and Humphrey automated perimetry results in a clinical population.
BACKGROUND/AIMS The purpose of the study was to evaluate patients' ease of understanding of Damato campimetry assessment and to determine the sensitivity and specificity of the results compared with Humphrey automated perimetry. METHODS Patients underwent Humphrey perimetry and Damato campimetry on the same day. Patients were excluded if they were unable to undergo Humphrey perimetry. Results...
متن کاملA comparison of manual kinetic and automated static perimetry in obtaining ptosis fields.
OBJECTIVE To compare examination time and visual field loss for ptosis fields obtained with manual kinetic (Goldmann) perimetry and automated static (Humphrey) perimetry. METHODS Both eyes of 12 patients with bilateral aponeurogenic ptosis were prospectively examined using Goldmann and Humphrey (ptosis protocol) perimetry with the eyelids ptotic and taped into a normal position. RESULTS Bil...