Eustachian Tube Opening Measurement by Sonotubometry Using Perfect Sequences for Healthy Adults
نویسندگان
چکیده
OBJECTIVES The aim of this study was to establish the rate variation of sonotubometric measurements using a specific broadband class of signals, the so-called perfect sequences (PSEQ) among healthy adults and to identify an optimal and technically simple test to provoke Eustachian tube (ET) openings. METHODS Sonotubometry was performed on 105 healthy adult subjects. Three different consecutive maneuvers were performed for ET opening: dry swallowing, water swallowing (a small [2 mL] and a large [5 mL] water bolus). Values of the amplitude and duration of each measured ET opening were calculated. RESULTS A total of 6,300 measurements were performed. Sonotubometric ET openings were detected for all subjects but not for each measurement. In 6,180 of 6,300 measurements (98.1%), objective ET openings were registered. In 11 of 105 subjects (10.5%) at least one sonotubometric ET opening was not detected. The mean ET opening duration time and the mean sound amplitude similar for all performed test and were 270 (SD, ±96) msec, 13.48 (SD, ±6.57) dB. CONCLUSION Sonotubometry based on PSEQ stimuli is a reliable methodology to assess the ET opening function in healthy subjects. Mean ET opening duration time and the mean sound wave amplitude performed similarly in all analysed tests, hence it might be concluded that dry (saliva) and water swallowing are reliable sonotubometric maneuvers and may be used when examining ET opening function. The size of a sip during water swallowing does not affect the sonotubometry result. All maneuvers can be equally used as the optimal test, and water swallow is most comfortable for the subject.
منابع مشابه
Sonotubometry in children with otitis media with effusion before and after insertion of ventilation tubes.
OBJECTIVES To test the outcome of sonotubometric measurement in children with otitis media with effusion (OME) before and after insertion of ventilation tubes. DESIGN Eustachian tube ventilatory function was tested in children with OME. To test validity, sonotubometric testing took place before insertion of ventilation tubes (ie, glue ear) and 1 week and 3 months after grommet insertion (ie, ...
متن کاملValidation of sonotubometry in healthy adults.
BACKGROUND Frequent active opening of the eustachian tube (ET) allows ventilation of the middle ear and equilibration of pressure changes. Active opening is accomplished by the contraction of the paratubal muscles during swallowing. Because a disturbance of the ventilatory function of the ET may contribute to the development of otitis media with effusion, it is important to investigate ET funct...
متن کاملRelationship between the electromyographic activity of the paratubal muscles and eustachian tube opening assessed by sonotubometry and videoendoscopy.
OBJECTIVE To determine the role played by the tensor veli palatini and levator veli palatini muscles (mTVP and mLVP, respectively) in eustachian tube (ET) opening. DESIGN Prospective study. SETTING Research laboratories at a tertiary care hospital. PATIENTS Fifteen healthy adults with normal middle ears and documented ET openings. INTERVENTIONS Submental and ground surface electrodes we...
متن کاملEustachian tube function in patients with eosinophilic otitis media associated with bronchial asthma evaluated by sonotubometry.
OBJECTIVE To determine eustachian tube function in patients with asthma and with or without eosinophilic otitis media (EOM), a new middle ear disease entity with a highly viscous middle ear effusion containing many eosinophils and usually associated with bronchial asthma. One of the most important causes of otitis media (OM) is eustachian tube dysfunction. DESIGN Retrospective case review. ...
متن کاملSonotubometry: a useful tool to measure intra-individual changes in eustachian tube ventilatory function.
OBJECTIVE To determine whether intra-individual changes in eustachian tube (ET) function induced by local application of a histamine phosphate solution can be detected using an improved sonotubometer. DESIGN The function of the ET was measured with a revised sonotubometer before and after histamine was applied to the nasopharyngeal ostium of the ET. SETTING Tertiary referral hospital. PAT...
متن کامل