Fixation of the femoral condyles: a mechanical comparison of small and large fragment screw fixation.

نویسندگان

  • Afshin Khalafi
  • Scott Hazelwood
  • Shane Curtiss
  • Philip Wolinsky
چکیده

BACKGROUND To compare the stability achieved using two 6.5-mm screws versus two or four 3.5-mm screws for the fixation of a unicondylar distal femur fracture. METHODS A fracture model was created in femoral synthetic composite bones to simulate a lateral femoral condyle fracture (AO/OTA 33-B1). Fixation was performed using three different types of screw constructs: 1) two 6.5-mm cancellous screws inserted using the lag technique, 2) two 3.5-mm cortical screws inserted using the lag technique, and 3) four 3.5-mm cortical screws, with two inserted using the lag technique and two as position screws. After reduction and fixation, the constructs were axially loaded in a material-testing machine. Main outcome measurements were the mean load required to displace the osteotomy site 1 and 2 mm as well as the mean stiffness of the different fixation methods. RESULTS The 6.5-mm construct required 56% more load to displace the osteotomy fragment 1 mm than the two 3.5-mm construct required (p < 0.0001), and 40% more load than the four 3.5-mm construct required (p < 0.0001). At loads that caused 2 mm of osteotomy displacement, these differences increased to 62% (p < 0.0001) and 48% (p < 0.0001), respectively. The mean loads needed to displace the osteotomy site were 28% higher for 1 mm of displacement (p = 0.003) and 27% higher for 2 mm of displacement (p = 0.03) for the four 3.5-mm screw construct compared with those needed for the two 3.5-mm group. The mean stiffness for the 6.5-mm group (1312.5 N/mm) was significantly higher than for the four 3.5-mm construct (784.2 N/mm; p < 0.0001) and the two 3.5-mm screw construct (409.4 N/mm; p < 0.0001). The difference in stiffness between the 3.5-mm groups was significant as well (p < 0.0001). CONCLUSION Stabilization of a unicondylar distal femur fracture with two 6.5-mm cancellous screws provides the most rigid and stable fixation. If small fragment screws are used, a minimum of four 3.5-mm cortical screws should be used to approximate the mechanical stability of two 6.5-mm screws.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intrapelvic Protrusion of a Broken Guide Wire Fragment during Fixation of a Femoral Neck Fracture

  During fixation of a femoral neck fracture in a 23-year-old male patient with cannulated screws, a broken guide wire fragment inadvertently advanced through the hip joint and protruded into the pelvis. A second surgical approach was needed to remove the broken fragment from the pelvis. Awareness of such a potentially devastating complication will make surgeons more cautious during implementa...

متن کامل

Intrapelvic Protrusion of a Broken Guide Wire Fragment during Fixation of a Femoral Neck Fracture

Breakage of DHS guide wire during surgery and its migration into the pelvis through the hip joint is a rare complication and its removal can be very challenging for the surgeon. We share our experience of a similar case wherein we used an ‘iliofemoral’ approach to successfully remove the broken transfixing guidewire from the hip joint. Although iliofemoral approach is similar to the lateral win...

متن کامل

Biomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery

  Background: Ligament reconstruction is a common procedure in orthopedic surgery. Although several popular techniques are currently in use, new methods are proposed for secure fixation of the tendon graft into the bone tunnel. Purposes: We sought to introduce our new technique of Bashti bone plug for fixation of soft tissue graft in anterior cruciate ligament (ACL) reconstruction and to compar...

متن کامل

Isolated Buttress Plating of Posterior Wall Acetabular Fractures: Is it Sufficient?

Background: Conventional fixation methods of posterior wall acetabular fractures feature the use of plating and lagscrews. However, fixation of posterior wall fractures with buttress plating alone offers potential advantages by avoidingthe hardware complications related to hardware placement through the wall fragment. The purpose of this study wasto examine if buttress plating...

متن کامل

A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate

Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of trauma

دوره 64 3  شماره 

صفحات  -

تاریخ انتشار 2008