Focal spot measurements using a digital flat panel detector.
نویسندگان
چکیده
Focal spot size is one of the crucial factors that affect the image quality of any x-ray imaging system. It is, therefore, important to measure the focal spot size accurately. In the past, pinhole and slit measurements of x-ray focal spots were obtained using direct exposure film. At present, digital detectors are replacing film in medical imaging so that, although focal spot measurements can be made quickly with such detectors, one must be careful to account for the generally poorer spatial resolution of the detector and the limited usable magnification. For this study, the focal spots of a diagnostic x-ray tube were measured with a 10-μm pinhole using a 194-μm pixel flat panel detector (FPD). The two-dimensional MTF, measured with the Noise Response (NR) Method was used for the correction for the detector blurring. The resulting focal spot sizes based on the FWTM (Full Width at Tenth Maxima) were compared with those obtained with a very high resolution detector with 8-μm pixels. This study demonstrates the possible effect of detector blurring on the focal spot size measurements with digital detectors with poor resolution and the improvement obtained by deconvolution. Additionally, using the NR method for measuring the two-dimensional MTF, any non-isotropies in detector resolution can be accurately corrected for, enabling routine measurement of non-isotropic x-ray focal spots. This work presents a simple, accurate and quick quality assurance procedure for measurements of both digital detector properties and x-ray focal spot size and distribution in modern x-ray imaging systems.
منابع مشابه
Measurement of focal spot size with slit camera using computed radiography and flat-panel based digital detectors.
The purpose of this study was to evaluate the use of digital x-ray imaging detectors for the measurement of diagnostic x-ray tube focal spot size using a slit camera. Slit camera images of two focal spots for a radiographic x-ray tube were acquired with direct-exposure film (DF) (as specified by the National Electrical Manufacturers Association [NEMA] Standards Publication No. XR 5, 1992), comp...
متن کاملGeneralized Penalized Weighted Least-Squares Reconstruction for Deblurred Flat-Panel CBCT
An increase in achievable spatial resolution would enable application of flat-panel detector cone-beam CT (FPCBCT) in high-resolution applications, such as 3D breast and bone imaging. Improved reconstruction techniques exploiting more sophisticated models of noise and spatial resolution characteristics may provide such improvement. In this work, we propose a statistical model of measurement mea...
متن کاملExamining nanoparticle assemblies using high spatial resolution x-ray microtomography
An experimental system has been designed to examine the assembly of nanoparticles in a variety of process engineering applications. These applications include the harvesting from solutions of nanoparticles into green parts, and the subsequent sintering into finished components. The system is based on an x-ray microtomography with a spatial resolution down to 5 mm. The theoretical limitations in...
متن کاملThe effect of focal spot size on the spatial resolution of variable resolution X-ray CT scanner
Background: A variable resolution X-ray (VRX) CT scanner provides a great increase in the spatial resolution. In VRX CT scanners, the spatial resolution of the system and its field of view (FOV) can be changed according to the object size. One of the main factors that limit the spatial resolution of VRX CT scanner is the effect of the X-ray focal spot. Materials and Methods: A theoreti...
متن کاملDigital Radiography Using Flat Panel Detector for the Non-Destructive Evaluation of Space Vehicle Components
Digital technology has been introduced into radiography very recently but the conventional film based technique will be totally out of the arena in no time as what has happened in the photography field. The state-of-art technology is direct digital Xray imaging based on Flat Panel Detector technology in which the X-ray image is displayed on the computer without the intermediate optics or mechan...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Proceedings of SPIE--the International Society for Optical Engineering
دوره 9033 90335F شماره
صفحات -
تاریخ انتشار 2014