Arrhythmia Termination Versus Elimination of Dormant Pulmonary Vein Conduction as a Procedural End Point of Catheter Ablation for Paroxysmal Atrial Fibrillation: A Prospective Randomized Trial.
نویسندگان
چکیده
BACKGROUND Pulmonary vein isolation (PVI) is still associated with a substantial number of arrhythmia recurrences in paroxysmal atrial fibrillation (AF). This prospective, randomized study aimed to compare 2 different procedural strategies. METHODS AND RESULTS A total of 152 patients undergoing de novo ablation for paroxysmal AF were randomized to 2 different treatment arms. The procedure in group A consisted of PVI exclusively. In this group, all isolated PVs were challenged with adenosine to reveal and ablate dormant conduction. In group B, PVI was performed with the patient either in spontaneous or in induced AF. If AF did not terminate with PVI, ablation was continued by targeting extra-PV AF sources with the desired procedural end point of termination to sinus rhythm. Primary study end point was freedom from arrhythmia during 1-year follow-up. In group A, adenosine provoked dormant conduction in 31 (41%) patients with a mean of 1.6±0.8 transiently recovered PVs per patient. Termination of AF during PVI was observed in 31 (65%) patients, whereas AF persisted afterward in 17 (35%) patients. AF termination occurred in 13 (76%) patients by AF source ablation. After 1-year follow-up, significantly more group B patients were free of arrhythmia recurrences (87 versus 68%; P=0.006). During redo ablation, the rate of PV reconduction did not differ between both groups (group A: 55% versus group B: 61%; P=0.25). CONCLUSIONS Elimination of extra-PV AF sources after PVI is superior to sole PV isolation with the adjunct of abolishing potential dormant conduction. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT02238392.
منابع مشابه
Arrhythmia Termination Versus Elimination of Dormant Pulmonary Vein Conduction as a Procedural End Point of Catheter Ablation for Paroxysmal Atrial Fibrillation
D espite intensive research during the past 15 years in the field of catheter ablation for paroxysmal atrial fibrillation (AF), recurrence rates after pulmonary vein isolation (PVI) remain as high as 30% to 40% after a single procedure even in highly experienced centers. Two different mechanisms have been basically identified to be responsible for this procedural limitation: (1) electric recove...
متن کاملMultielectrode Pulmonary Vein Isolation Versus Single Tip Wide Area Catheter Ablation for Paroxysmal Atrial Fibrillation
Catheter ablation (CA) is an accepted treatment option for symptomatic atrial fibrillation (AF). Historically, CA has been performed with a point-by-point technique, using standard focal radiofrequency catheters and 3-dimensional (3D) navigation systems, with a procedural end point of electric pulmonary vein isolation (PVI). However, this CA approach requires advanced training and operator skil...
متن کاملAdenosine-guided radiofrequency catheter ablation of atrial fibrillation: A meta-analysis of randomized control trials
BACKGROUND The prognostic significance of adenosine-mediated dormant pulmonary vein conduction, and whether such dormant conduction should be eliminated, remains controversial. We sought to perform a meta-analysis of data from eligible studies to delineate the prognostic impact of adenosine-guided radiofrequency catheter ablation of atrial fibrillation. METHODS A systematic literature search ...
متن کاملMultielectrode Pulmonary Vein Isolation Versus Single Tip Wide Area Catheter Ablation for Paroxysmal Atrial Fibrillation: A Multinational Multicenter Randomized Clinical Trial.
BACKGROUND Single-shot ablation techniques may facilitate safe and simple pulmonary vein isolation to treat paroxysmal atrial fibrillation. Multielectrode pulmonary vein isolation versus single tip wide area catheter ablation-paroxysmal atrial fibrillation is the first multinational, multicenter, prospective, noninferiority randomized clinical trial comparing multielectrode-phased radiofrequenc...
متن کاملClinical implication of adenosine test at repeat atrial fibrillation ablation procedure: the importance of detecting dormant thoracic vein conduction.
BACKGROUND Pulmonary vein reconnection after electrical isolation is commonly observed in the context of atrial fibrillation ablation and is associated with recurrent atrial tachyarrhythmias. Adenosine test was been performed to identify acute dormant conduction immediately after pulmonary vein isolation at index procedure. However, the utility of adenosine test at repeat procedure has not been...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation. Arrhythmia and electrophysiology
دوره 8 5 شماره
صفحات -
تاریخ انتشار 2015