Two-dimensional and 3-dimensional optical coherence tomographic imaging of the airway, lung, and pleura.

نویسندگان

  • N Hanna
  • D Saltzman
  • D Mukai
  • Z Chen
  • S Sasse
  • J Milliken
  • S Guo
  • W Jung
  • H Colt
  • M Brenner
چکیده

BACKGROUND Methods for obtaining real-time in vivo histologic resolution by means of noninvasive endoscopic optical imaging would be a major advance for thoracic surgical diagnostics and treatment. Optical coherence tomography is a rapidly evolving technology based on near-infrared interferometry that might provide these capabilities. The purpose of this study is to investigate the feasibility of real-time 2- and 3-dimensional optical coherence tomographic imaging of airway, pleural, and subpleural lung tissues in normal, inflammatory, and malignant animal models and patients with known or suspected airway malignancy. METHODS Freshly excised lungs and pleural tissue obtained from rabbits with inhalation lung injury and induced empyema, metastatic sarcomas, and pleural sarcomas and from patients with airway disease were imaged by using 2- and 3-dimensional optical coherence tomography with a prototype superluminescent diode optical coherence tomographic system constructed in our laboratory. Lungs and pleural tissue were subsequently processed for standard hematoxylin and eosin histology for comparison with optical coherence tomography. RESULTS Optical coherence tomographic imaging achieved an ex vivo resolution of 10 microm and an in vivo resolution of about 30 microm with a depth penetration of 1 to 2 mm with 2- and 3- dimensional reconstruction capabilities. Tumors as small as 500 microm were detectable with optical coherence tomography. The acquired images closely matched histologic images, demonstrating details at the level of mucosal layers, glands, alveoli, and respiratory bronchioles. CONCLUSIONS Optical coherence tomography with near-infrared interferometric methods enables near real-time in vivo near-histologic resolution optical imaging. With further advances, optical coherence tomography has the potential for real-time accurate and early pleural and subpleural diagnostics by using small-diameter flexible fiberoptic endoscopic probes for a wide range of thoracic surgical applications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Two-dimensional Simulation of Mass Transfer and Nano-Particle Deposition of Cigarette Smoke in a Human Airway

The chance of developing lung cancer is increased through being exposed to cigarette smoke illustrated by studies. It is vital to understand the development of particular histologic-type cancers regarding the deposition of carcinogenic particles, which are present in human airway. In this paper, the mass transfer and deposition of cigarette smoke, inside the human airway, are investigated apply...

متن کامل

Three-dimensional Fourier domain optical coherence tomography in vivo imaging of alveolar tissue in the intact thorax using the parietal pleura as a window.

In vivo determination of 3-D and dynamic geometries of alveolar structures with adequate resolution is essential for developing numerical models of the lung. A thorax window is prepared in anesthetized rabbits by removal of muscle tissue between the third and fourth rib without harming the parietal pleura. The transparent parietal pleura allows contact-free imaging by intravital microscopy (IVM...

متن کامل

Development of an Advanced Optical Coherence Tomography System for Radiation Dosimetry

Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...

متن کامل

In vivo lung microvasculature visualized in three dimensions using fiber-optic color Doppler optical coherence tomography.

For the first time, the use of fiber-optic color Doppler optical coherence tomography (CDOCT) to map in vivo the three-dimensional (3-D) vascular network of airway segments in human lungs is demonstrated. Visualizing the 3-D vascular network in the lungs may provide new opportunities for detecting and monitoring lung diseases such as asthma, chronic obstructive pulmonary disease, and lung cance...

متن کامل

Use of three-dimensional ultrasonography of the eye and measurement of optical long axis in dog

This study was conducted to determine the use of three-dimensional ultrasonography (3DU) in ocular imaging of the dog and measuring of its optical axis. 12 healthy mixed-breed dogs including 6 males and 6 females were studied. 3DU of the eyes were done using a 5–12 MHz linear trapezoid transducer. 3DU of the eyes were evaluated and the normal optical long axis through a line between the cornea ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of thoracic and cardiovascular surgery

دوره 129 3  شماره 

صفحات  -

تاریخ انتشار 2005