Pulmonary vein isolation: the impact of pulmonary venous anatomy on long-term outcome of catheter ablation for paroxysmal atrial fibrillation.
نویسندگان
چکیده
BACKGROUND Circumferential pulmonary vein (PV) isolation is the cornerstone of catheter ablation for atrial fibrillation (AF); however, PV reconnection remains problematic. OBJECTIVE To assess the impact of PV anatomy on outcome after AF ablation. METHODS One hundred two patients with paroxysmal AF underwent cardiac magnetic resonance (60%) or computed tomography (40%) before AF ablation. PV anatomy was classified according to the presence of common PVs, accessory PVs, PV branching pattern, and the dimensions of the PV ostia, intervenous ridges (IVRs), and the left PV-left atrial appendage ridge. RESULTS Four discrete PVs were present in 48(47%) of the patients: a left common PV in 38(37%), a right common PV in 2(2%), an accessory right PV in 20(20%), and left PV in 4(4%). At a mean follow-up of 12 ± 4 months, 75 of 102 (74%) patients were free of recurrent AF. A LCPV was associated with an increase in freedom from AF (87% vs 66% for 4 PV anatomy; P = .03). Greater left IVR length (16.9 ± 3.5 mm vs 14.0 ± 3.0 mm; P ≤ .001) and width (1.4 ± 0.6 mm vs 1.1 ± 0.6 mm; P = .02) were associated with increased AF recurrence. After multivariate analysis, abnormal anatomy (LCPV or accessory PV) and left IVR length were found to be the only independent predictors of freedom from AF. CONCLUSIONS Four discrete PVs are present in the minority of patients with paroxysmal AF undergoing PV isolation. The presence of a LCPV is associated with an increased freedom from AF after catheter ablation. PV anatomy may in part explain the variable outcome to electrical isolation in patients with paroxysmal AF.
منابع مشابه
Myocardial neuroendocrine tumour metastasis mimicking melanoma: multimodality imaging diagnosis.
Tilz RR et al. Impact of pulmonary vein anatomy assessed by cardiac magnetic resonance imaging on endo-scopic pulmonary vein isolation in consecutive patients. Impact of pharmacological autonomic blockade on complex fractionated atrial electrograms. A et al. Prospective assessment of late conduction recurrence across radiofrequency lesions producing electrical disconnection at the pulmonary vei...
متن کاملImages and Case Reports in Arrhythmia and Electrophysiology Successful Transseptal Puncture and Cryoballoon Pulmonary Vein Isolation in Adverse Anatomy Interrupted Inferior Caval Vein and Azygos Continuation
A 56-year-old male patient was admitted for catheter ablation of highly symptomatic paroxysmal atrial fibrillation. During the procedure, a rare anatomic variation with an interrupted inferior caval vein (ICV) branching suprarenal into an azygos venous continuation draining into the superior caval vein was detected. Using angiography, a continuation of the ICV leading into the liver, subdividin...
متن کاملImpact of variant pulmonary vein anatomy and image integration on long-term outcome after catheter ablation for atrial fibrillation.
AIMS To investigate the impact of variant pulmonary vein (PV) anatomy and the use of three-dimensional image integration (3D-II) on long-term efficacy of catheter ablation for atrial fibrillation (AF). METHODS Consecutive procedures from 2002 to 2007 were analysed from a prospective database. All patients underwent wide area circumferential ablation, with linear lesions added and complex frac...
متن کاملCatheter ablation of atrial fibrillation facilitated by preprocedural three-dimensional transesophageal echocardiography: Long-term outcome
AIM To evaluate the long-term outcome of catheter ablation of atrial fibrillation (AF) facilitated by preprocedural three-dimensional (3-D) transesophageal echocardiography. METHODS In 50 patients, 3D transesophageal echocardiography (3D TEE) was performed immediately prior to an ablation procedure (paroxysmal AF: 30 patients, persistent AF: 20 patients). The images were available throughout ...
متن کاملParoxysmal atrial fibrillation ablation: Achieving permanent pulmonary vein isolation by point-by-point radiofrequency lesions
Pulmonary vein isolation by point-by-point radiofrequency catheter ablation constitutes the cornerstone of catheter ablation strategies for the treatment of atrial fibrillation. However, despite advances in pulmonary vein isolation ablation strategies, long-term success rates after ablation remain suboptimal, which highlights the need to develop techniques to achieve more durable lesions. Strat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Heart rhythm
دوره 11 4 شماره
صفحات -
تاریخ انتشار 2014