Characterisation of the mobility on isoelectric focusing of individual proteins in CSF and serum by immunofixation.

نویسندگان

  • M A Laurenzi
  • H Link
چکیده

The mobility of 17 different proteins in CSF and serum on isoelectric focusing was investigated by subsequent immunofixation using monospecific antisera. Individual proteins yielded identical, often complex band patterns in normal CSF and serum, except transferrin which gave one to two additional bands between pH 5.8-6.4, and the low molecular wieght beta-trace protein and gamma-trace protein, which gave three bands at pH 7.4, 8.0, and 8.4, and a single band at pH 9.5, respectively, on investigation of CSF but not serum. Polyclonal IgC migrated as multiple bands between pH 4.7-8.6. Oligoclonal IgG in CSF in multiple sclerosis and neurosyphilis migrated between pH 8.6-9.5 and was easily discriminated from other proteins.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی ترکیبات گلیکوزیله نهایی آلبومین سرم (AGE) در افراد دیابتی به روش ایزوالکتریک فوکوسینگ (IEF) و فلورسانس جهت ارزیابی پیشرفت بیماری دیابت

Background: The non-enzymatic glycosylation (NEG) of proteins in diabetes damages both the structure and function of these proteins. In vivo and in vitro studies have shown that NEG of proteins and advanced glycosylation end-products (AGE) contribute to the pathogenesis of both macrovascular, such as atherosclerosis, and microvascular complications, such as retinopathy and nephropathy, in diabe...

متن کامل

Detection of CSF leakage by isoelectric focusing on polyacrylamide gel, direct immunofixation of transferrins, and silver staining.

Detection of CSF Leakage by Isoelectric Focusing on Polyacrylamide Gel, Direct Immunofixation of Transferrins, and Silver Staining, Freek W.C. Roelandse,* Nico van der Zwart, Jan H. Didden, Jenny van Loon, and John H.M. Souverijn (Dept. of Clin. Chem., Leiden Univ. Medical Centre, Albinusdreef 2, 2333 ZA Leiden, The Netherlands; *author for correspondence: fax 1 31/71/5266753, e-mail roelandse@...

متن کامل

Factitious proteinuria: diagnosis and protein identification by use of isoelectric focusing.

Factitious proteinuria is an unusual finding. We present a case in which clinical suspicion was aroused by the disparity between the clinical history and findings and the 24-h excretion of protein in urine. Electrophoresis of the patient's serum and urine confirmed the presence of an unusual protein. By isoelectric focusing we identified it as egg-white, a finding confirmed by immunofixation wi...

متن کامل

Detection of IgG oligoclonal bands in unconcentrated CSF by isoelectric focusing in ultrathin polyacrylamide gel, direct antiserum immunofixation and silver nitrate staining.

Isoelectric focusing of proteins in ultrathin polyacrylamide gel (0.4 mm), followed by direct immunofixation with monospecific antisera and silver nitrate staining, is a highly specific, sensitive and simple method for the detection of oligoclonal IgG in unconcentrated CSF samples. The ultrathin polyacrylamide gels have several advantages, i.e. significantly smaller amounts of reagents are requ...

متن کامل

Quality versus quantity: which is better for cerebrospinal fluid IgG?

An article in this issue (1 ) reopens an old question: Is qualitative or quantitative testing of immunoglobulins in cerebrospinal fluid (CSF) more diagnostically useful? The short answer is that each has pros and cons. In the diagnosis of multiple sclerosis, it can be misleading to perform only quantitative analysis, but it is much less problematic to perform only qualitative analysis (2 ). To ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of neurology, neurosurgery, and psychiatry

دوره 42 4  شماره 

صفحات  -

تاریخ انتشار 1979