Beamstop with integrated X-ray sensor.

نویسندگان

  • Paul J Ellis
  • Aina E Cohen
  • S Michael Soltis
چکیده

A versatile beamstop with an integrated sensor has been developed at the Stanford Synchrotron Radiation Laboratory (SSRL) using non-specialized components. A diameter of 1.5 mm was achieved using a commercial subminiature surface mount PIN diode (Phillips BAP64) molded into a tungsten epoxy composite cup. The cup is supported on a thin fiberglass arm with printed circuit traces to transmit the signal from the diode. The assembly has an active area of approximately 100 micro m in diameter. As the diode is encapsulated in plastic, the response diminishes with decreasing energy but is still useful at 6 keV.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A small and robust active beamstop for scattering experiments on high-brilliance undulator beamlines

A small active in-vacuum beamstop has been developed to monitor the flux of intense third-generation synchrotron X-ray beams protecting the downstream detector from the direct beam. Standard active beamstops, where a built-in diode directly absorbs the beam, have limitations in size and lifetime. In the present design, a silicon PIN diode detects the photons back-scattered from a cavity in the ...

متن کامل

Design and Simulation of Hot Cathode Ionization Vacuum Gauge with no X-Ray Limitations

In this paper, the MEMS type ionization gauge with no X-Ray limitations has been presented. Having the dimensions of 2.4 mm× 0.8mm × 1.4 mm, the designed gauge is 9000 times smaller than the conventional type and can operate in HV and UHV pressures up to 5×10-9 torr. Operating at the temperature of 750°C, the cathode of proposed gauge is implemented using nickel and works in a way in...

متن کامل

A nearly on-axis spectroscopic system for simultaneously measuring UV–visible absorption and X-ray diffraction in the SPring-8 structural genomics beamline

UV-visible absorption spectroscopy is useful for probing the electronic and structural changes of protein active sites, and thus the on-line combination of X-ray diffraction and spectroscopic analysis is increasingly being applied. Herein, a novel absorption spectrometer was developed at SPring-8 BL26B2 with a nearly on-axis geometry between the X-ray and optical axes. A small prism mirror was ...

متن کامل

A New Sensor Based on Graphite Screen Printed Electrode Modified With Cu-Nanocomplex for Determination of Paracetamol

Paracetamol is a non-steroidal anti-inflammatory drug used as an antipyretic agent for the alternative to aspirin. Conversely, the overdoses of paracetamol can cause hepatic toxicity and kidney damage. Hence, the determination of paracetamol receives much more attention in biological samples and also in pharmaceutical formulations. Here, we report a rapid<span id="transmark" style="display: non...

متن کامل

(Resonant) Hard X-ray Ptychography for High-Sensitivity Imaging with Chemical Contrast

The investigation of innovative materials and chemical processes requires deep insight into their respective morphology and dynamics. Equally important is the knowledge of the chemical distribution in terms of elements and oxidation states. For this purpose, highresolution X-ray imaging is an important tool in nanoscience to analyse individual features of various kinds of specimens such as hete...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of synchrotron radiation

دوره 10 Pt 3  شماره 

صفحات  -

تاریخ انتشار 2003