Implant-supported overdentures with different bar designs: A retrospective evaluation after 5-19 years of clinical function
نویسندگان
چکیده
PURPOSE This retrospective study evaluated the outcome of implant-retained overdentures (IODs) after 5-19 years of clinical function. MATERIALS AND METHODS A retrospective analysis of patient files was performed referring to 27 patients who received 36 IODs with 3 different bar designs (group A=prefabricated round bars, n=7; group B=one-piece anterior milled bars, n=20; and group C=two bilaterally placed milled bars, n=9) in the mandible (n=24) and/or in the maxilla (n=12). The analysis focused on the survival and success rates (according to Kaplan-Meier) of the implants and prostheses. Technical complication rates for each type of restoration were analyzed and compared via one-way ANOVA and the Chi-squared test. The prevalence of peri-implantitis (radiographic bone loss ≥3.5 mm) was evaluated by digital analysis of panoramic radiographs taken post-operative (baseline) and after 5-19 years of clinical function (follow-up). RESULTS The mean observational time was 7.3 years. The survival rates of the prostheses and implants were 100% and 97.7%, respectively. Technical complications occurred more frequently in group A (mean: 3.5 during observational time) than in the other two groups (B: 0.8; C: 1.0). However, this difference was not statistically significant (P=0.58). Peri-implantitis was diagnosed for 12.4% of the implants in 37% of the patients. CONCLUSION Bar-retained IODs are an adequate treatment option for edentulous jaws. These restorations may exhibit high implant/prosthesis survival rates (>97%), and a limited incidence of technical complications after a mean observational period of >7 years. Nevertheless, peri-implantitis was identified as a frequent and serious biological complication for this type of reconstruction.
منابع مشابه
Comparison of the Effect of Ball and Bar Attachment Designs on Retention and Stability of Mandibular Implant-Supported Overdentures
Objectives: The present study evaluated the effect of bar and ball attachment designs on retention and stability of a mandibular overdenture supported by four implants. Methods: An edentulous mandibular acrylic resin model with four implants in the anterior part of the ridge (A, B, D and E) was fabricated. A metal framework simulating the overdenture was also fabricated. Totally, 30...
متن کاملComparison of stresses transferred to the implant supported overdentures with bar, ball and zaag attachments through photoelasticity
Comparison of stresses transferred to the implant supported overdentures with bar, ball and zaag attachments through photoelasticity Dr. A. Saboori* - Dr. Gh. Esfahanizade** - Dr. M. Ejlali*** *- Assistant Professor of Prosthodontics Dept. - Faculty of Dentistry – Shaheed Beheshti University of Medical Sciences. **- Assistant Professor of Prosthodontics Dept. - Faculty of Dentistry – Tehran Isl...
متن کاملMorse taper connection implants supporting "planned" maxillary and mandibular bar-retained overdentures: a 5-year prospective multicenter study.
OBJECTIVES In contrast to the excellent long-term outcomes described for implant-supported mandibular overdentures, less favorable long-term survival and success rates have been reported for maxillary implants supporting overdentures. The aim of this study was to evaluate the treatment outcome of "planned" bar-retained maxillary and mandibular overdentures supported by Morse taper connection im...
متن کاملMaxillary overdentures retained by splinted and unsplinted implants: a retrospective study.
The purpose of this retrospective study was to evaluate the clinical performance of and patients' satisfaction with maxillary overdentures retained by splinted and unsplinted implants. Patients who had been treated with maxillary implant-retained overdentures because of functional problems with conventional complete dentures were identified and invited to participate in the study. A total of 16...
متن کاملOverdentures supported by ASTRA TECH Implant SystemTM
Prospective clinical studies with the ASTRA TECH Implant System show that the survival rate of implants placed in the mandible is the same when comparing overdentures and fixed bridges, irrespective of retaining system used . The use of a ball abutment or a Locator for a non-splinted support, as well as the use of a bar attachment for a splinted support, is well documented with a followup of 1–...
متن کامل